Working with integers
In the data lists, the following data format is used for integer data such as "16-bit signed integer":
Bit order and byte order are illustrated in the following example (general little-endian system).
Example: The setting for 350 (decimal) = 0 × 015E (hexadecimal) in the 16-bit range of offset 9–10 looks
like this.
Working with negative numbers
For negative numbers, the two's complement representation is used. For example, when using 8-bit signed
integers, "−1" corresponds to "0 × FF" and "−128" corresponds to "0 × 80".
13.4.2 Simplified table for output data
The following table provides simplified information on output data transmitted from the external device
(master) to the welding power source (slave).
13.4.4 Details of I/O data on page EN
MSB ←
→
← LSB
Offset 10 (larger offset)
Offset 9 (smaller offset)
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
0
0
0
0
0
0
1
0
1
0
1
1
1
1
0
0
1
5
E
Tab. 55
Simplified table for output data
Offset
Bit
Function
Description
0
0
Weld start
1: starting the welding
process
0: stopping the welding
process
0
1
Wire feed
1: start wire feed
0: end wire feed
0
2
Wire retraction
1: start wire retraction
0: end wire retraction
0
3
Gas rinsing
1: start gas rinsing
0: end gas rinsing
0
4
Weld detection
1: start detection
0: end detection
0
7
Watchdog
1: activated
0: not activated
1
–
Operation stop
1: operation stop
0: remove operation stop
2
0
Save location number for
welding condition
(job memory)
0: current welding conditions
1 to 100: save location number for welding
conditions
3
1
Load job memory
1: execute load
0: do not execute
procedure
3
7
Write job memory
1: execute write
0: do not execute
procedure
3
–
Permission to change settings 1: permissible
0: impermissible
4–5
–
Welding mode
4
0–1
TRAVEL SPEED
Selects the travel speed.
Tab. 59 Setting the travel speed on
page EN
4
2–4
WELDING METHOD
Selects the welding procedure.
Tab. 60 Setting the welding procedure on
page EN
4
5–7
SHIELDING GAS TYPE
Selects the shielding gas type.
Tab. 61 Setting the shielding gas type on
page EN
5
0–3
WELDING WIRE MATERIAL Selects the welding wire material.
Tab. 62 Setting the welding wire material on
page EN
5
4–6
WELDING WIRE DIAMETER Selects the welding wire diameter.
Tab. 63 Setting the welding wire diameter on
page EN
5
7
Penetration control
1: valid
0: invalid