9 Maintenance and cleaning
EN
-
91
9.6 Maintenance work on the Wire Buffer KINETIC
9.6.1 Replacing the wire guide
1
Loosen the hexagon socket screws
.
2
Remove the power fitting
3
.
4
Reattach the power fitting
with a tightening torque of 6.2 Nm.
9.6.2 Replacing the wire guide and guide rollers in the Wire Buffer KINETIC
1
Loosen the knurled screws (6×)
.
2
Loosen the hexagon socket screws (2×)
and remove the upper part of the wire guide clamp
3
Loosen the hexagon socket screws with screw locking rings (4×)
and remove the guide roller
covers (2×)
Fig. 49
Replacing the wire guide
A
Wire guide
B
2× hexagon socket screws (M5 × 25)
C
Power fitting
A
C
B
Fig. 50
Removing the covers
A
Cover
B
6× knurled screw
C
2× hexagon socket screw (M3 × 12)
D
Wire guide clamp
E
2× guide roller cover
F
4× hexagon socket screw with screw locking ring
B
A
E
F
C
D