![Abicor Binzel iROB 501 PRO Скачать руководство пользователя страница 70](http://html2.mh-extra.com/html/abicor-binzel/irob-501-pro/irob-501-pro_original-operating-instructions_5036310070.webp)
EN
-
70
7 Operation
iROB
®
501 PRO
F68: setting current change values (start welding parameter)
The present value of the start welding parameter can be set in % based on the present value of the welding
parameter.
F69: setting current change values (end crater parameter)
The present value of the end crater parameter can be set in % based on the present value of the welding
parameter
F77: assigning the power source ID
No function.
F82: starting pulse time configuration (for aluminum)
Set the pulse time for the start of the arc. Used when starting pulse welding with aluminum wire.
F83: setting the number of pulses during the start process (for aluminum)
Used for mX Kinetic welding with aluminum wire. Increasing the value increases the heat input at the start of
the arc. Lowering the value reduces the heat input at the start of the arc.
F84: starting the pulse feed setting (for aluminum)
Used for mX Kinetic welding with aluminum wire. Increasing the value shortens the arc length. Decreasing
the value increases the arc length.
Adjustable range
10 to 300%
Default value
100%
Storage option
No
Description
Defines the current value of the start parameter as a percentage based
on the present welding current.
Adjustable range
10 to 300%
Default value
100%
Storage option
No
Description
Defines the current value of the end crater filling parameter as a
percentage based on the present welding current.
Adjustable range
0 to 2 s
Default value
0.3 s
Storage option
No
Description
Defines the time of the pulses at the moment the arc starts.
Adjustable range
0 to 300%
Default value
100%
Storage option
No
Description
Defines the number of pulses at the moment the arc starts.
Adjustable range
200 to −99
Default value
0
Storage option
No
Description
Defines the arc length during the start pulse period.