![Abicor Binzel iROB 501 PRO Скачать руководство пользователя страница 31](http://html2.mh-extra.com/html/abicor-binzel/irob-501-pro/irob-501-pro_original-operating-instructions_5036310031.webp)
iROB
®
501 PRO
6 Commissioning
EN
-
31
Creating connections to the wire feed control unit/welding power source
1
Connect the encoder cable X4a to the Pull Feeder KINETIC motor cable connector
control unit.
2
Connect the encoder cable X6a to the Pull Feeder KINETIC encoder cable connector
on the wire
feed control unit.
3
Connect the motor cable X7a to the Wire Buffer KINETIC control lead connector
on the wire feed
control unit.
4
Connect the Wire Buffer KINETIC control lead X1a to the connector
on the welding power source.
5
Connect the welding torch control lead X2a to the connector
6.10 Connecting the wire conduit
1
Attach the wire conduit to the Push Feeder KINETIC’s guide adapter.
Fig. 11 Push Feeder KINETIC structure on page EN
2
Attach the other end of the wire conduit to the wire conduit connector on the Wire Buffer KINETIC.
Fig. 13 Wire Buffer KINETIC structure on page EN
Fig. 27
Connections on the wire feed control unit (back)
A
Wire Buffer KINETIC control lead connector X7a
B
Pull Feeder KINETIC encoder cable connector X6a
C
Pull Feeder KINETIC motor cable connector X4a
Fig. 28
Connectors on the welding power source
A
Wire Buffer KINETIC control lead connector X1a
B
Welding torch control lead connector X2a
A
B
C
A
B