![Abicor Binzel iROB 501 PRO Скачать руководство пользователя страница 21](http://html2.mh-extra.com/html/abicor-binzel/irob-501-pro/irob-501-pro_original-operating-instructions_5036310021.webp)
iROB
®
501 PRO
4 Product description
EN
-
21
4.6 Technical data for the wire feed control unit
4.6.1 Controller KINETIC wire feed control unit
4.6.2 Push Feeder KINETIC
Tab. 5
Ambient conditions for transport and storage
Ambient temperature
(transport and short-term storage)
−10°C to +50°C
Ambient temperature
(storage)
+15°C to +35°C
Relative humidity
(transport and short-term storage)
20% to 80% (non-condensing)
Relative humidity
(storage)
45% to 65% (non-condensing)
Other storage requirements
No harmful vapors in the vicinity
No applied current
Tab. 6
Ambient conditions for operation
Ambient temperature
0°C to +40°C
Relative humidity
20% to 80% (non-condensing)
Tab. 7
General data for the wire feed control unit
Number of controlled axes
2
Drive system
AC servo motor
Position feedback
Absolute encoder
Power supply
3 phases AC 400 V ±15% 50/60 Hz
Power
0.2 kVA
(depends on use and movement pattern)
Earth resistance
<100 Ω
Weight
23 kg
Dimensions (L × W × H)
685 × 392 × 206 mm
Tab. 8
General data for Push Feeder KINETIC
Roll system
2-roll drive
Drive system
AC servo motor
Welding process
CO
2
/ MAG /MIG
Welding wire type
Solid steel wire ø 0.8 mm, ø 1.0 mm, ø 1.2 mm
Solid stainless steel wire ø 1.0 mm, ø 1.2 mm
Aluminum wire ø 1.0 mm (hard aluminum only),
ø 1.2 mm, ø 1.6 mm
Solder wire ø 1.0 mm, ø 1.2 mm
Quantity of wire feed
Max. 30 m/min.
Weight
4.1 kg
Dimensions (L × W × H)
146 × 136 × 165