C
<Parameter setting> knob
Adjusts the selected parameter value (welding current, welding
voltage, or wire feed speed).
D
<Toggle welding current/wire
feed speed> button
Selects the welding current and wire feed speed.
The value is displayed in the left digital display and can be
adjusted via the parameter setting function. The mode can be
switched by pressing the button.
E
<Toggle voltage> button
Selects the welding voltage.
The value is displayed in the right digital display and can be
adjusted via the parameter setting function. If synergy mode has
been selected for adjusting the voltage, the displayed value can
be switched between the absolute value and the correction value
by pressing the button. In synergy mode, the voltage is adjusted
according to the welding current. The basis of the characteristic
curve value is ± 0. This value is used for fine tuning.
F
<Parameter selection> button
Switches between the welding parameters (shielding gas pre-
flow time, starting current, main current, end current, and
shielding gas post-flow time).
During welding, the set value can be displayed on the digital
display.
G
<Function> button
Selects internal functions.
If the button is pressed for 1 second or longer, the LED illuminates
and the internal function mode is switched on.
H
<Gas check> button
Allows shielding gas to flow.
When the button is pressed, the LED illuminates and shielding gas
is emitted. After 2 minutes, the shielding gas flow stops
automatically. When the button is pressed again, the LED
extinguishes and the shielding gas flow stops.
I
<Wire feed> button
Feeds the welding wire.
When the button is pressed, the LED illuminates and welding wire
is fed. The wire feed speed can be adjusted via the <Parameter
setting> knob. If an analog remote control is connected, the wire
feed speed can be adjusted via the current setting on the analog
remote control.
J
<Welding speed> selection
button
Selects the desired welding speed.
The selection option depends on the installed options.
The LED for the selected welding speed illuminates. Some
combinations of welding wire diameter, welding wire material,
shielding gas type, and welding procedure are not sensible. If an
impermissible combination is selected, the LED flashes.
Tab. 1
Control elements
Pos. Name
Function