BCN PRESSURE TRANSMITTER
CALIBRATION
G
-
9
D-to-A Adjust
The D-TO-A ADJUST selection is only present when you are in the ANA-
LOG communication mode, specified in the configuration procedure. This
selection allows you to adjust the four to 20 milliampere output of the field
device.
Key
Display
Comments
This operation will cause a change in output not cor-
responding to the input. Be sure the control loop is in
manual.
Select YES.
Select D-TO-A ADJUST.
Use the arrow keys to adjust the 4 mA signal.
NOTE: When increasing or decreasing the mA sig-
nal, the increments of change increase with succes-
sive depressions until the maximum level of change
is reached. By changing direction you will return to
the smallest increment of change. This adjustment
technique speeds up the adjustment process without
affecting fine adjustment.
Use the up and down arrow keys to adjust the 20 mA
signal.
C A LI-
B R AT E
OUTPUT WILL BE
AFFECTED! PROCEED?
NO
→
YES
E N T E R
CALIBRATION
→
D-TO-A ADJUST
BENCH CALIB.
REZERO
E N T E R
ADJUST TO 4 mA
THEN HIT ENTER
E N T E R
ADJUST TO 20 mA
THEN HIT ENTER
E N T E R
ID TAGNAME
READY