background image

 

  

Manual

Содержание 28000

Страница 1: ...Manual...

Страница 2: ...5 1 The Connecting Sockets 6 5 2 Power Supply for the Base Unit 6 5 3 Power supply for Add on Units 6 5 4 Connecting Lightning Sound 7 5 5 Connecting an external Amplifier 8 5 6 Connecting the LocoNe...

Страница 3: ...intensity by LNCV programming according to one s own wish The system can be used with analog and digital layouts The lighting system is powered with a normal Model railway transformer 2 The Components...

Страница 4: ...lighting effect correctly with sunrise morning red and sunset evening red as well as the night effect two white and one coloured unit are required A 3m long layout can be illuminated with a basic unit...

Страница 5: ...ate vertically on side panels of the lamp boxes The serrated edges top and bottom of joiners will hold them tight in the lamp box Ensure that you use the end of the housing which has the joining cable...

Страница 6: ...to the base of the housing Bore an 8mm hole in the base and feed the cable through Connect the two ends to a transformer We recommend our 150VA transformer Part No 20150 to power the system This tran...

Страница 7: ...stem must not have any electrical connection to the wiring of the model railway layout 5 4 Connecting Lightning Sound The Lightning Sound add on unit consists of two parts the flash lightning unit and...

Страница 8: ...button keys Any normally open momentary push button switch can be used as keys Connect the switches and the LED to the 5 way plug as shown in the diagram Insert the plug into connector 2 of the base...

Страница 9: ...lights and Halogen to maximum intensity and hold clock 6 2 Operating using Key switches analog If the lighting system is used with an analog DC or AC layout or a digital center which does not have a L...

Страница 10: ...f the time by hand the change flows through to the light system at the latest after the time period in the display s LNCV 35 8 Programming LocoNet devices are setup using LocoNet configuration variabl...

Страница 11: ...the new value for the LNCV The value is programmed by pressing the key Used the key so a new LNCV can be selected Used the key to select another module Or the menu key to leave programming mode As wit...

Страница 12: ...7 Reduction of the model time relative to the standard time factor 1 100 LNCV value 5 100 5 8 Reduction of the events relative to the standard time factor 1 100 LNCV value 5 100 5 9 Time when starting...

Отзывы: