11
referenced during programming. The factory default address of an
IntelliLight module is 1. If further IntelliLight Base units are controlled by a
centre they must have different module addresses. Valid addresses are 1
to 65534.
8.2 Reading and programming of an IntelliLight Module
Similarly to DCC locomotive decoders
,
IntelliLight modules operation is
setup in various configuration variables (CV). Contrary to locomotive
decoders they are not programmed via the rails but via the LocoNet and are
therefore called LocoNet CV’s (LNCV’s).
•
After calling up the IntelliLight module (see Chapter 8.1) the Intellibox
display shows:
The cursor blinks under the 0.
•
At the cursor position, enter the ID number of the LNCV that is to be
programmed.
•
Press the [
]-key.
•
The Intellibox reads the LNCV and the value is displayed on the right of
the lower line.
•
Use the [
]-key to move the cursor to the right field and enter the new
value for the LNCV.
•
The value is programmed by pressing the [
]-key.
•
Used the [
]-key so a new LNCV can be selected.
•
Used the [
]-key to select another module.
•
Or the [menu]-key to leave programming mode
As with the Intellibox, the numbers marked by the blinking cursor can be
incremented by pressing the [
+
]-key and decremented with the [
]-key.
8.3 The Universal Address 65535
As the name implies, the universal address can be used to call up any
IntelliLight module. The universal address is not a valid address that can be
used for identifying different IntelliLight modules. It can only be used for
calling up modules whose real address is not known. For this only the
particular module that is being tested can be connected to the LocoNet. If
the module is then called up the current address can then be read from
LNCV 0.
This is the procedure:
•
Press the [menu]-key
•
Press the [mode]- key
•
Using the [
]-key scroll down to the “LocoNet Prog.“ menu
•
Press the [
]-key
•
Enter the part number (the IntelliLight base unit is 28000)
•
Enter the universal address 65535
•
Press [
]-key
•
The module’s address from LNCV 0 will be read and displayed.
Содержание 28000
Страница 1: ...Manual...