109
Current protection
Chapter 11
Verifying settings by secondary
injection
6.7.1
Checking the phase current operate value, IP>
The check of the
IP>
current level is best made in
FunctionMode=Current
and
BuTripMode=
“1 out of 3” or “2 out of 4”
.
Procedure
1.
Apply the fault condition, including start of BFP, with a current below
set IP>.
2.
Repeat the fault condition and increase the current in steps until a
trip occurs.
3.
Compare the result with the set IP>.
4.
Disconnect AC and start input signals.
Note: If “No I> check” or “Retrip off” is set, only back-up trip can be
used to check set
IP>
.
6.7.2
Checking the residual (EF) current operate value “IN>” set below “IP>”
The check of low set IN> current level is best made in F
unciontMode= Current
and
BuTrip-
Mode= “1 out of 4”.
Procedure
1.
Apply the fault condition, including start of BFP, with a current just
below set IN>.
2.
Repeat the fault condition and increase the current in steps until trip
appears.
3.
Compare the result with the set IN>.
4.
Disconnect AC and start input signals.
6.7.3
Checking the re-trip and back-up times
The check of the set times can be made in connection with the check of operate values above.
Choose the applicable function and trip mode, such as
FunctMode= Current a
nd
RetripMode =
I> check.
Procedure
1.
Apply the fault condition, including start of BFP, well above the set
current value. Measure time from “Start of BFP”.
2.
Check the re-trip t1 and back-up trip times t2 and t3
In applicable cases the back-up trip for multi-phase start “t2MPh” and
back-up trip 2, “t2 + t3” can also be checked. For check of “t2MPh” a
two-phase or three-phase start shall be applied.
3.
Disconnect AC and start input signals.
6.7.4
Verifying the re-trip mode
Choose the mode below, which corresponds to the actual case. In the cases below it is assumed
that
FunctionMode = Current
is selected.
Содержание RELION REL670
Страница 8: ...Contents ...
Страница 54: ...46 Checking the optical connections Chapter 6 Checking the external optical and electrical connections ...
Страница 72: ...64 About this chapter Chapter 9 Establishing connection and verifying the LON communication ...
Страница 78: ...70 Downloading settings and configuration from a PC Chapter 10 Configuring the IED and changing settings ...
Страница 174: ...166 Remote communication Chapter 11 Verifying settings by secondary injection ...
Страница 190: ...182 Maintenance Chapter 13 Fault tracing and repair ...
Страница 198: ...190 Glossary Chapter 14 Glossary ...