HVC
‐
PD
E
‐
Bus
Charger
Installation
Guide
Document: V1.2 / Document No.: 6AGA000008-0629-EN | Date: 06-30-2022 Page
117
of
146
X2
Pantograph heater cable
1
Wire 1
ACS L Heater
2
Wire 2
ACS N Heater
PE2 GND
(green/yellow)
GND
X3 X4
Interlock / DC Guard cable
5 Shield
GND
1 White
Interlock
In
2 Brown
Interlock
Out
3
DC_Guard_A
4
DC_Guard_GND
X3 X4
Next Interlock / next DC Guard cable
(only for sequential mode)
6
5
Next_Interlock_In
6
Next_Interlock_Out
7
Next_DC_Guard_A
8
Next_DC_Guard_GND
X3 X4
Pantograph CP/PE cable
4 Shield
GND
9 Wire
1
CP
10
Wire
2
PE
X3 X4
ACS Control cable
1 Wire
1
ACS
+24V
2 Wire
2
ACS
-24V
3 GND
(green/yellow) GND
11
Wire 3
ACS Extend/Retract Out
12
Wire 4
ACS Magn Reed In
13
Wire 5
ACS Supply/Retract Out
14
Wire 6
ACS Retracted In
15
Wire 7
ACS Magn Supply Out
16
Wire
8
ACS
GND_B
17
Wire 9
ACS Extended In
X4
EMO cable
19 Wire
1
EMO
S1
20 Wire
2
EMO
S1
21 Wire
3
EMO
S2
22 Wire
4
EMO
S2
X4
Beacon cable
23 Wire
1
Beacon
PCB1_OUT1
24 Wire
2
Beacon
PCB1_OUT2
25 Wire
3
Beacon
PCB3_OUT3
26 Wire
4
Beacon
PCB4_+24V
X4
Distance sensor cable
31
Wire 1
Distance 24V
33
Wire 2
Distance Sensor NO/NC
32
Wire 3
Distance Sensor GND
34
Wire 4
Distance Sensor Analog out
13. Tighten the connector screws with a tightening torque of 1.0 ft-lb.