HVC
‐
PD
E
‐
Bus
Charger
Installation
Guide
Document: V1.2 / Document No.: 6AGA000008-0629-EN | Date: 06-30-2022 Page
106
of
146
7. Screw at the back side of the lighting protection connection a toothed washer (D) and a
nut (F) on the bolt (C).
8. Tighten the bolt with a tightening torque of 11 ft-lb.
5.16.4. Gland
layout
of the ACS Control Module
Gland #
Clamping range ØF
Cable
1
5 – 10 mm (0.20 – 0.39 Inch)
AC utility power
2
5 – 10 mm (0.20 – 0.39 Inch)
Pantograph heater
3
5 – 10 mm (0.20 – 0.39 Inch)
Interlock
4
5 – 10 mm (0.20 – 0.39 Inch)
Pantograph CP/PE
5
10 - 17 mm (0.39 – 0.67 Inch)
RFID Ethernet
6
5 – 10 mm (0.20 – 0.39 Inch)
EMO switch
7
5 – 10 mm (0.20 – 0.39 Inch)
Beacon
8
5 – 10 mm (0.20 – 0.39 Inch)
Not used
9
5 – 10 mm (0.20 – 0.39 Inch)
Temperature sensor
10
10 - 17 mm (0.39 – 0.67 Inch)
RFID Power cable
11
13 – 21 mm (0.51 – 0.83 Inch)
Communication (fibers)
12
13 – 21 mm (0.51 – 0.83 Inch)
ACS Control
13
13 – 21 mm (0.51 – 0.83 Inch)
PE (GND)
14
27 – 35 mm (1.07 – 1.38 Inch)
DC+ In (from HVC 150, primary)
15
27 – 35 mm (1.07 – 1.38 Inch)
DC+ In (from HVC 150S, secondary 1)
16
27 – 35 mm (1.07 – 1.38 Inch)
DC+ Out (to pantograph)
17
27 – 35 mm (1.07 – 1.38 Inch)
DC+ Out (to pantograph)
18
27 – 35 mm (1.07 – 1.38 Inch)
DC+ Out (to pantograph)
19
27 – 35 mm (1.07 – 1.38 Inch)
Not used
20
27 – 35 mm (1.07 – 1.38 Inch)
DC+ In (from HVC 150S, secondary 2)
21
27 – 35 mm (1.07 – 1.38 Inch)
Not used
22
10 - 17 mm (0.39 – 0.67 Inch)
DC- OVP Sensing