Range
Description
Field(s)
–
The values of the request. In case of an odd
number of bytes, a zero byte is appended to en-
sure the word structure of the telegram.
Values
1)
1)
Only if Response ID is 01h (Request Parameter OK). The Format, Numberof Values and Values fields are repeated for
other parameters.
The table below shows the data types for the Format field in the PROFIdrive response.
Type
Code
(Reserved)
0x00
Standard data types
0x01…0x36
1. Boolean (not supported)
2. Integer8 (not supported)
3. Integer16
4. Integer32
5. Unsigned8 (not supported)
6. Unsigned16
7. Unsigned32
8. Floating point (not supported)
9. Visible string (not supported)
…
(Reserved)
0x37…0x3F
Zero
0x40
Byte
0x41
Word
0x42
Double word
0x43
Error
0x44
(Reserved)
0x45…0xFF
The table below shows the PROFIdrive parameter request error codes.
Used at
Meaning
Error #
Access to an unavailable parameter
Impermissible parameter number
00h
Change access to a parameter value that cannot be
changed
Parameter value cannot be changed
01h
Change access with a value outside the limits
Low or high limit exceeded
02h
Access to an unavailable subindex
Invalid subindex
03h
Access with a subindex to a non-indexed parameter
No array
04h
Change access with a value that does not match the
data type of the parameter
Incorrect data type
05h
Change access with a value unequal to 0 when this is
not permitted
Setting not permitted (can only be reset)
06h
Change access to a description element that cannot
be changed
Description element cannot be changed
07h
PROFINET IO – Communication protocol 95
Содержание FSPS-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSPS 21 safety functions fieldbus module User s manual ...
Страница 2: ......
Страница 4: ......
Страница 11: ...Further information Table of contents 11 ...
Страница 12: ...12 ...
Страница 26: ...26 ...
Страница 38: ...38 ...
Страница 42: ...42 ...
Страница 46: ...46 ...
Страница 69: ...Configuring safety PLC 1 Select safety telegram to use on slot 2 Leave slot 1 empty PROFINET IO Start up 69 ...
Страница 72: ...Switch or router ABB drive ABB drive ABB drive PLC Safety PLC 72 PROFINET IO Start up ...
Страница 86: ...86 ...
Страница 136: ... Configuring FSPS 21 with TIA14 1 Open TIA and create a new project 2 Select your CPU from the list 136 PROFIsafe ...
Страница 144: ...19 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 20 Insert values to blocks 144 PROFIsafe ...
Страница 147: ...26 In device configuration right click FSPS icon and select Assign device name PROFIsafe 147 ...
Страница 155: ...Select Addresses tab to see the correct IO addresses PROFIsafe 155 ...
Страница 169: ...6 To check the Device number of the FSPS 21 module select the General tab PROFIsafe 169 ...
Страница 178: ... starting the system does not cause any danger 178 Start up ...
Страница 186: ...186 ...
Страница 192: ...192 ...
Страница 200: ...200 ...
Страница 208: ...208 ...
Страница 212: ......