![ABB FSPS-21 Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/abb/fsps-21/fsps-21_user-manual_2729052.webp)
Default
Description
Name/Value
No.
N/A
This parameter is not used by the adapter module
when the module is configured for PROFINET IO.
Reserved
23
0
Sets the PROFIsafe destination address, that is, the
address of the FB module in the safety communication
network.
F Destination Address
24
Note:
This address must be the same as is set in the F-
Parameters for the PROFIsafe module properties
(F_Dest_Add).
For more information, see section
0
Allows defining the PROFINET station name.
PN Name Index
25
By default this value is 0 and the station name is set
from the network. When the value is set to other than
0, the PROFINET station name is overwritten in the
format “abbdrive-xx”, where xx is the value of the
parameter name index.
Example: Setting this value to 12 results in the name
“abbdrive-12”.
Note:
During every boot the FSPS-21 module checks the
value of PN Name Index,
• If the value is not Zero then the active PN Name In-
dex overrides the PROFINET station name.
• If the new name is set by DCP Set command as
permanent, the new name is used and stored to
flash. The PN Name Index parameter value is not
changed, so after next boot, the name is taken ac-
cording to the PN Name Index.
• If the new name is set by DCP Set command as
temporary, the new name is used and the empty
name is stored to flash. The PN Name Index para-
meter value is not changed, so after next boot name
is taken according to the PN Name Index.
• The PROFINET DCP factory reset also resets the
PN Name Index value to default (0).
0...65535
0
= Done
Validates any changed adapter module configuration
parameter settings. After refreshing, the value reverts
automatically to 0 = Done.
FBA A/B par refresh
27
Note:
This parameter cannot be changed while the drive is
running.
Refreshing done
0
= Done
Refreshing
1
= Refresh
52 PROFINET IO – Start-up
Содержание FSPS-21
Страница 1: ... OPTIONS FOR ABB DRIVES FSPS 21 safety functions fieldbus module User s manual ...
Страница 2: ......
Страница 4: ......
Страница 11: ...Further information Table of contents 11 ...
Страница 12: ...12 ...
Страница 26: ...26 ...
Страница 38: ...38 ...
Страница 42: ...42 ...
Страница 46: ...46 ...
Страница 69: ...Configuring safety PLC 1 Select safety telegram to use on slot 2 Leave slot 1 empty PROFINET IO Start up 69 ...
Страница 72: ...Switch or router ABB drive ABB drive ABB drive PLC Safety PLC 72 PROFINET IO Start up ...
Страница 86: ...86 ...
Страница 136: ... Configuring FSPS 21 with TIA14 1 Open TIA and create a new project 2 Select your CPU from the list 136 PROFIsafe ...
Страница 144: ...19 In ABB_Drive FB add blocks DPRD_DAT and DPWR_DAT 20 Insert values to blocks 144 PROFIsafe ...
Страница 147: ...26 In device configuration right click FSPS icon and select Assign device name PROFIsafe 147 ...
Страница 155: ...Select Addresses tab to see the correct IO addresses PROFIsafe 155 ...
Страница 169: ...6 To check the Device number of the FSPS 21 module select the General tab PROFIsafe 169 ...
Страница 178: ... starting the system does not cause any danger 178 Start up ...
Страница 186: ...186 ...
Страница 192: ...192 ...
Страница 200: ...200 ...
Страница 208: ...208 ...
Страница 212: ......