![background image](http://html.mh-extra.com/html/abb/fdna-01/fdna-01_user-manual_184137.webp)
Communication protocol 137
ODVA Serial Number:
This attribute is a number used in conjunction with the Vendor ID to
form a unique identifier for each device on DeviceNet. The value of
this attribute is 02000000h plus the SERNO value from the device
label.
Product Name:
This text string should represent a short description of the
product/product family represented by the product code in attribute
3.
State:
Represents current state of the identity object
DeviceNet object, class 03h
The DeviceNet object provides the configuration and status of a
DeviceNet port. Each DeviceNet product must support one (and
only one) DeviceNet object per physical connection to the
DeviceNet communication link.
Class attributes
Value
State
0
Nonexistent
1
Device Self Testing
2
Standby
3
Operational
4
Major Unrecoverable Fault
5
Minor Unrecoverable Fault
#
Attribute
name
Class attributes
(Instance #0)
Description
Data
type
1
Revision
Get
Revision of the
DeviceNet Object Class
Definition on which the
implementation is based
UINT8
Содержание FDNA-01
Страница 1: ...Options for ABB drives converters and inverters User s manual FDNA 01 DeviceNet adapter module ...
Страница 2: ...List of related manuals See section Related manuals on page 16 ...
Страница 4: ......
Страница 14: ...14 Safety ...
Страница 22: ...22 About the manual ...
Страница 32: ...32 Electrical installation ...
Страница 72: ...72 Start up 3 Configure the device MAC address ...
Страница 76: ...76 Start up ...
Страница 96: ...96 Communication profiles ...
Страница 154: ...154 Communication protocol ...
Страница 162: ...162 Technical data ...
Страница 166: ...166 Appendix A Varying the number of drive parameters ...