Communication profiles 83
ODVA input attributes
This section briefly describes the instances found in the input
assemblies of the ODVA AC/DC drive profile. Note that all input
assembly instances do not support all attributes listed here.
Faulted (Control supervisor object)
This attribute indicates that the drive has experienced a fault. The
fault code may be read from the FaultCode attribute of the Control
supervisor object.
Warning (Control supervisor object)
This attribute indicates that the drive is experiencing a warning
condition. The warning code may be read from the WarnCode
attribute of the Control supervisor object.
Running Forward (Control supervisor object)
This attribute indicates that the drive is running in the forward
direction.
Running Reverse (Control supervisor object)
This attribute indicates that the drive is running in the reverse
direction.
Ready (Control supervisor object)
This attribute indicates that the Control supervisor object state
machine is in the Ready, Running or Stopping state. See State
(Control supervisor object) on page 60.
Ctrl From Net (Control supervisor object)
This attribute indicates if the Run/Stop command is being supplied
locally (Ctrl From Net = 0) or by the network (Ctrl From Net = 1).
Ref From Net (AC/DC drive object)
This attribute indicates if the Speed and Torque References are
being supplied locally (Ref From Net = 0) or by the network (Ref
From Net = 1).
Содержание FDNA-01
Страница 1: ...Options for ABB drives converters and inverters User s manual FDNA 01 DeviceNet adapter module ...
Страница 2: ...List of related manuals See section Related manuals on page 16 ...
Страница 4: ......
Страница 14: ...14 Safety ...
Страница 22: ...22 About the manual ...
Страница 32: ...32 Electrical installation ...
Страница 72: ...72 Start up 3 Configure the device MAC address ...
Страница 76: ...76 Start up ...
Страница 96: ...96 Communication profiles ...
Страница 154: ...154 Communication protocol ...
Страница 162: ...162 Technical data ...
Страница 166: ...166 Appendix A Varying the number of drive parameters ...