Communication profiles 95
Actual values
Actual values are 16-bit signed two's complement integers
containing information on the operation of the drive. A negative
reference indicates a reverse direction of rotation. The functions to
be monitored are selected with a drive parameter.
Scaling
Actual values are scaled as shown below.
Note:
The values of REF1 MAX and REF2 MAX are set with drive
parameters. See the drive documentation for further information.
0
REFx MAX
-(REFx MAX)
0
ACT2: -10000
ACT1: -20000
ACT2: 10000
ACT1: 20000
Drive
Fieldbus