68 Start-up
The table below gives the recommended drive parameter settings.
Drive parameter
Setting for
ACS880 drives
Description
50.01 FBA A enable
1
= Enable
Enables communication between
drive and adapter module.
50.04 FBA A ref1 type
4
= Speed
Selects Speed as the fieldbus A
reference 1 type.
50.05 FBA A ref2 type
3
= Torque
Selects Torque as the fieldbus A
reference 2 type.
51.01 FBA type
DeviceNet
1)
Displays the type of the adapter
module.
51.02 MAC ID
6
Defines the MAC ID number of the
adapter module.
51.03 Baud rate
0
= 125kbit/s
Sets the baud rate for the DeviceNet
interface.
51.06 Output instance
23
Selects the ABB Drives profile with
speed and torque plus drive
parameters output instance.
51.07 Output num pars
10
Must always be set to 10. For
exceptions, see
Appendix A –
Varying the number of drive
parameters
.
51.27 FBA par refresh
1
= Configure
Validates the FDNA-01 configuration
parameter settings.
19.11 Ext1/Ext2 selection
3
= DI1
Selects digital input DI1 as the
source for the external control
location EXT1/EXT2selection.
19.12 Ext1 control mode 1
2
= Speed
Selects speed control as the control
mode 1 for external control location
EXT1.
19.14 Ext2 control mode 1
3
= Torque
Selects torque control as the control
mode 1 for external control location
EXT2.
20.01 Ext1 commands
12
= Fieldbus A
Selects fieldbus interface A as the
source of the start and stop
commands for external control
location EXT1.
Содержание FDNA-01
Страница 1: ...Options for ABB drives converters and inverters User s manual FDNA 01 DeviceNet adapter module ...
Страница 2: ...List of related manuals See section Related manuals on page 16 ...
Страница 4: ......
Страница 14: ...14 Safety ...
Страница 22: ...22 About the manual ...
Страница 32: ...32 Electrical installation ...
Страница 72: ...72 Start up 3 Configure the device MAC address ...
Страница 76: ...76 Start up ...
Страница 96: ...96 Communication profiles ...
Страница 154: ...154 Communication protocol ...
Страница 162: ...162 Technical data ...
Страница 166: ...166 Appendix A Varying the number of drive parameters ...