RQ Series Unified Feature String Nomenclature
GE
N
M
JR
EV
SIZ
E
SE
RIE
S
M
NR
EV
VL
T
A1
A2
A3
A4
A5
B1
B2
B3
B4
B5
1 2
3A
3B
3C
3D
3E
4A
4B
4C
5A
5B
5C
5D
5E
6A
6B
6C
6D
6E
7 8
9A
9B
9C
9D
RQ A - 030 - C - 0 - 3 - C A B 0 A
-
0 0 0 0 0 : 0 1 - 0 A G 0 K - E 0 0 - 0 0 0 0 0 - 0 0 0 0 0 - C A - 0 0
0 0
-
0 0 - 0 0 - 0 - 0 0 0
- 0 0 - B A 0 B - 0 0 - 0 0 0 - A 0 0 0 0 0 - C 0 0 0 0 0 - 0 0 0 0 0 0 B
10A
10B
11A
11B
12
13A
13B
13C
14
15
16A
16B
16C
16D
17A
17B
18A
18B
18C
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
9C: FINAL FILTER TYPE
0 = No Final Filters
9D: FILTER OPTIONS
0 = None
A = Clogged Filter Switch - Unit Filters
B = Clogged Filter Switch - Unit + Energy Recovery
Filters
E = Magnehelic Gauge - Unit Filters
F = Magnehelic Gauge - Unit + Energy Recovery
Filters
J = Clogged Filter Magnehelic Gauge - Unit
Filters
K = Clogged Filter Magnehelic Gauge -
Unit + Energy Recovery Filters
Feature 10: REFRIGERATION CONTROL
10A: REFRIGERATION CONTROL
A = 5 Minute Compressor Off Timer and 20 Second
Compressor Stage Delay
D = Adjustable Compressor Lock Outs
E = Freeze Stats (each circuit)
P = Option D + E
10B: Refrigeration Control B
0 = None
Feature 11: REFRIGERATION OPTIONS
11A: REFRIGERATION OPTIONS
0 = None
E = Modulating Hot Gas Reheat
Q = Polymer E-Coated Modulating Hot Gas Reheat
11B: Refrigeration Options B
0 = Standard Packaged Unit
12: REFRIGERATION ACCESSORIES
0 = None
A = Sight Glass
B = Compressor Isolation Valves
C = Option A + B
D = One Circuit 0
°
F Low Ambient
Feature 13: POWER OPTIONS
13A: UNIT DISCONNECT TYPE
0 = Standard Power Block
A = Non-Fused Disconnect Power Switch
B = Circuit Breaker
13B: DISCONNECT 1 SIZE
0 = Power Block
A = 15 amps
B = 20 amps
C = 25 amps
D = 30 amps
E = 35 amps
F = 40 amps
G = 45 amps
H = 50 amps
J = 60 amps
K = 70 amps
L = 80 amps
M = 90 amps
N = 100 amps
P = 110 amps
Q = 125 amps
R = 150 amps
S = 175 amps
T = 200 amps
U = 225 amps
V = 250 amps
Z = 400 amps
3 = 600 Amps
13C: DISCONNECT 2 SIZE
0 = Standard - None
Содержание RQ NextGen Series
Страница 2: ......
Страница 26: ...26 Figure 3 RQ Cabinet Standard and Power Exhaust Gasket Locations...
Страница 40: ...40 Figure 23 Post Corner Hole Piping Figure 24 Post Back Hole Piping...
Страница 86: ...86 Figure 35 Example 2 6 ton through the Base Gas Piping Note RQ units will only contain one Heat Exchanger...
Страница 88: ...88 Gas Heater Operating Instructions Figure 36 Gas Heater Instructions...
Страница 95: ...95...
Страница 96: ...96...
Страница 105: ...105 Maintenance Log E Coated Coil...
Страница 107: ...107...