Page
19
of
44
3DGence Material Management System | version 1 | 03.2022
•
A 32A 3-phase adapter (included with the expansion module) that allows the 3-phase output to be split into three
individual phases. In this arrangement, the base unit and expansion module are connected to two of the three 1-phase
sockets, and the 3-phase plug is connected to the 3-phase mains with 32A overcurrent protection.
•
Directly connect the device to a separate 1-phase installation provided with 16A overcurrent protection.
•
In US conditions, the device must be connected to a power source equipped with separate 20A protection.
7.2.2.
Contents of the 3-chamber extension set
•
Expansion module
•
Assembly parts of the extension module to the base unit.
•
Set of drawers and desiccant cartridges.
•
32A 3 phase to 3x 1 phase power supply adapter.
7.2.3.
Preparation of devices for installation of the 3-chamber extension
The base unit to which the expansion module will be connected should be disconnected from the power supply and all its
chambers emptied and cooled.
1.
Remove the 5 mounting point plugs on the right-hand wall of the base unit (highlighted in red in the figure below).
Fig. 12 Location of the mounting point plugs in the base unit
2.
Using the screws from the set, install the angle bracket into the expansion module (highlighted in blue) as indicated
in the figure below. The second mounting plane should face to the left (towards the outer edge of the module).