17-6
Data Cards
Model No.
Running Head
OCU-DP Card User Screens and Settings
OCU-DP Card
The SR TS number selected will be the first segment occupied by this circuit. If a 19.2 kbps
circuit occupies two segments of the b-5 frame, selecting SR TS 1 will assign it to segments
1 and 2. Segments 3, 4 and 5 may be assigned independently to 9.6 kbps (or less) circuits from
other OCU-DP cards.
If a circuit is assigned that exceeds the slots necessary to accommodate it, such as a 19.2 kbps
circuit to SR TS 5 in b-5 framing, the message "Invalid SR TS" will be displayed. If a circuit
requires more space than the SR TS has available, such as a having a 19.2 kbps circuit assigned
to SR TS 1, a 19.2 kbps circuit assigned to SR TS 3 and then attempting to assign a 19.2 kbps
circuit to SR TS 4, the message "SR TS overlapping" will be displayed.
Figure 17-2.Data Frames, Rates, and Time Slot Assignments
MODE
The Mode setting options are ocu and csu. You should select ocu whenever the OCU-DP port
is attached to a DSU/CSU over a 4-wire circuit. In that mode, the OCU-DP port will generate
the necessary sealing current and the DSU/CSU will terminate it. The csu mode should not be
used unless you have two back-to-back OCU-DP ports. In that case, to achieve proper
orientation and sealing current, configure one of two OCU-DP ports for the ocu mode and the
other for the csu mode. The csu mode is not supported on the OCU-DP 5 Card, which has five
or ten ports.
a
b-5
b-10
b-20
56k
19.2k*
4.8k
2.4k
Framing
Maximum
TS #1
TS #2
TS #3
TS #4
WAN #1, Port #1 (w1-1)
Speed
* A 19.2 kbps circuit will occupy two contiguous 9.6 kbps subrate time slots.
Summary of Contents for IMACS 8000
Page 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Page 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Page 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Page 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Page 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Page 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Page 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Page 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Page 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Page 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Page 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Page 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Page 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Page 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Page 674: ...A 30 Reference Guide Model No Running Head...
Page 729: ...Pin Outs C 31 C 8 HSU Cards...