12-14
Voice Cards
Model No.
Running Head
FXS Card User Screens and Settings
FXS Card
Table 12-8. Test Screen Option Settings and Defaults
SIG MON
The Signaling Monitor feature works with the user card alarm system to detect excessive
signaling bit transitions. The system will generate alarms if the number of transitions of any
signaling bit in transmit or receive direction for an active port exceeds 255 in any four second
interval. The options are off and on, and they are toggled by pressing “g” (siGmon command)
in the Test Screen.
TEST
The Test parameter shows if the port is in test mode or not. Inactive ports and ports that are
assigned to inactive WANs will show a test status of n/a. The test status options for active
ports are off and on.
Tx ABCD
The Transmit ABCD setting allows the user to either monitor the status of the ABCD signaling
bits being transmitted towards the network or set a specific ABCD pattern for testing the
transmit side of the circuit. The options for this field are mon (monitor) or set. Choosing set
will bring up a four digit field for users to input the ABCD pattern they want to transmit. Any
four-digit combination of ones and zeros is acceptable for this setting.
Parameter
User Options
Default
SIG MON
off on
off
TEST
off on
off
Tx ABCD
mon set
mon
Rx ABCD
mon set
mon
T-R-CNTL
mon set
mon
TO USER
PCM 300Hz 1kHz 3kHz quiet
PCM
TO NTWK
PCM 300Hz 1kHz 3kHz quiet
PCM
Tx ABCD
Status information only; not editable
n/a
Rx ABCD
Status information only; not editable
n/a
T-R-CNTL
Status information only; not editable
n/a
T-R-STAT
Status information only; not editable
n/a
MODE
Status information only; not editable
n/a
TYPE
Status information only; not editable
n/a
STATUS
Status information only; not editable
n/a
Summary of Contents for IMACS 8000
Page 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Page 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Page 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Page 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Page 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Page 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Page 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Page 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Page 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Page 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Page 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Page 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Page 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Page 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Page 674: ...A 30 Reference Guide Model No Running Head...
Page 729: ...Pin Outs C 31 C 8 HSU Cards...