Data Cards
16-23
LDSRU-10P Card
SRU Card Specifications
16.8
SRU Card Specifications
SRU Card (Models 822060 and 822160)
Number of Ports
10
Physical Interface
female 8-pin RJ-48
Electrical Interface
RS232C, ITU-T V.28
Operational Interface
DCE - Full Duplex
Interface Settings
Asynchronous, Synchronous, V.14
Sub-rate Framing Format
X.50, V.14, DS0-A, DS0-B with 5, 10, or 20 divisions per DS0
Sub-rate Time slot Number
1 through 20 depending on Sub-rate Framing Format
Synchronous Data
Format
Transparent
Transmit Clocking
Software selectable per port; internal or external
Speeds
2.4, 4.8, 9.6, 14.4, 19.2, 28.8 and 38.4 kbps
Asynchronous Data
Format
V.14 or proprietary
Stop Bits
Software selectable per port; 1 or 2
Data Bits
Software selectable per port; 5, 6, 7 or 8
Parity
Software selectable per port; none, odd, even, space or mark
Speeds
.3, 1.2, 2.4, 4.8, 9.6, 14.4, 19.2, 28.8 and 38.4 kbps
Signaling
DSR
Tied to DTR
CTS
Software selectable per port; on, off (tied to RTS)
CTS delay
Software selectable per port; immediate, 30, 60 or 100 ms
RLSD
Software selectable per port; permanently on, follows remote RTS (drop on receipt
of IDLE or CGA RED)
Diagnostics & Alarms
BERT
Integral
Direction
Toward DTE or toward Network
Data Patterns
Off, mark, space, 1:1, 1:7, 511, 2047 zeros
Loopbacks
Local
Toward DTE or toward Network
Remote - Generation
Inband, latching, DDS format at CSU, DSU or OCU-DP
Remote - Detection
Inband, latching and non-latching DDS Format for OCU Loop, CSU Loop and
DSU Loop. Optional automatic ten (10) minute timeout
Error Correction
Majority Vote Error Correction
Available for DS0-A ports operating at 9.6 Kbps or less, triggers EER ALARM
when specified threshold is exceeded
Majority Vote Error Thresholds
None, 10e-3, 10e-4, 104-5, 10e-6 or 10e-7
Summary of Contents for IMACS 8000
Page 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Page 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Page 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Page 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Page 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Page 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Page 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Page 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Page 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Page 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Page 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Page 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Page 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Page 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Page 674: ...A 30 Reference Guide Model No Running Head...
Page 729: ...Pin Outs C 31 C 8 HSU Cards...