Reference Guide
4-5
Applications
Voice Modules
4.2.4
Voice Channel Bank Application
This is the simplest application which can be used by a service provider. The Integrated
Access System is used in this configuration when one or more digital T1/E1 trunks are needed
to interface with analog PBXs or key systems at the customer premises. In the US, the
break-even point for bringing in a T1 trunk as opposed to multiple analog lines is typically 6
analog lines. A single Integrated Access System can be used to provision up to 62 analog
POTS lines (FXS, FXO, E&M) on digital Central Office switches as shown in Figure 4-1.
Figure 4-1.An IAD used as a Voice Channel Bank
This Integrated Access System can also be deployed in applications which do just the reverse
of voice channel banks. This is most likely to be found in wireless local loop applications in
which the wireless service provider may use a state-of-the-art wireless local loop. The output
of the wireless base station is normally a T1/E1. However, the existing PSTN may still have
analog switches. The Integrated Access System is used to convert from robbed-bit
signaling/CAS to analog trunks.
The voice channel bank platform can be upgraded to provide an array of additional services
just by adding application modules to the chassis. It comes with a built-in suite of testing and
diagnostics tools which enhance the service and support capabilities significantly.
CAUTION:
For cont
inued
prot
ection
against fire
,
rep
lace
onl
y with th
e sam
e
typ
e and rating o
f fu
se
Pre
misy
s Co
mm
unic
atio
ns, I
nc.
Model IMA
CS/600
T 5A
250V
IEC
Fuse
5A SB
250V
UL/CSA
24/4
8V
5A
LIS
TED
9K0
9
LR 7
7063
120-20
0-240V
~
3A, 50 / 6
0 Hz
Tele
phone
Equ
ipment
Class
2 Po
wer S
ource
®
®
UL
+ -
+ -
+ -
R
G
R
C
O
M
VN
VB
VA
HSU
-T
530
/35
S
60
HSU-
T
530
/35
S 60
HSU
-T
530/35
S
60
HSU-
T
530
/35
S
60
HSU-
T
530
/35
S 6
0
HSU
-T
530
/35
S 60
BRI
HSU
530/35
S
60
P
2
P
1
P
4
P
3
FXO
8139
N
O
D
E
T
E
R
M
C
O
M
P
P
1
P
1
CPU
CLOC
K
NVR
AM
W1-1
CSU
W1
-2
DSX
WA
N
IF
T1+D
S1
Max 8 T1/E1
IAD
Local Digital
Switch
POTS/Class
62 POTS/Class Lines
Customer Premise
Central Office
D
S
X
P
a
n
e
l
Summary of Contents for IMACS 8000
Page 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Page 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Page 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Page 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Page 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Page 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Page 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Page 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Page 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Page 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Page 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Page 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Page 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Page 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Page 674: ...A 30 Reference Guide Model No Running Head...
Page 729: ...Pin Outs C 31 C 8 HSU Cards...