TCP/IP Network Management
Datagrams Delivered Above
The Datagrams Delivered Above field shows the number of datagrams sent to the TCP layer
of the network host to the local system.
Datagrams From Above
The Datagrams From Above field shows the number of information or traps sent by the local
system to the UDP or TCP layer of the network host.
Datagrams Sent
The Datagrams Sent field shows the total number of datagrams sent by the local system to the
network host.
TX Discarded - RAM
The TX Discarded - RAM field shows the total number of datagrams sent by the local system
that were discarded due to lack of free RAM memory.
TX Discarded - Mailbox Short
The TX Discarded - mailbox short field shows the total number of datagrams aborted by the
local system because of a mail subsystem overflow.
TX Discarded - Other
The TX Discarded - other field shows the total number of datagrams discarded due to other
causes.
7.4.2.4
ICMP Parameters
The ICMP parameters also appear in the second Network Statistics Screen (Figure 7-15). They
are described below.
Messages Sent
The Messages Sent field shows the number of ICMP messages sent by the local system to the
network host.
Summary of Contents for IMACS 8000
Page 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Page 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Page 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Page 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Page 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Page 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Page 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Page 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Page 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Page 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Page 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Page 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Page 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Page 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Page 674: ...A 30 Reference Guide Model No Running Head...
Page 729: ...Pin Outs C 31 C 8 HSU Cards...