The broad range of motor-drive solutions requires parametric configuration changes. To gain access to
configuration parameters, press ESC to reveal either the “Complete Menu”. With factory default parameters
installed, pressing ESC will reveal the complete menu.
To move around the menu system, press:
Press the
▲
FWD and
▼
REV buttons to display each menu item.
Press the
ENTER push button to enter a sub menu or change a parameter.
Press ESC to abandon a parameter change or exit a sub menu.
Press ESC several times in a row to return back to the operation displays.
After applying power it is recommended that you at least go through the
B00 MOTOR
,
C00 PERFORMANCE
and
G00 INPUT/OUTPUT
menus to set up the ZENER 8000-V before running the motor to prevent any unexpected
motor operation. The ZENER 8000-V is supplied with a link between the EN terminal and the +5V terminal. This
link must always be made for the motor to run.