ADJUSTMENTS
Parameter
Allowable range
Description
PWM EV2
(A)
0% ÷ 100%
(255 steps)
This parameter defines the duty-cycle of the PWM applied
to EV2 output (
A11
).
PWM EV3
(A)
0% ÷ 100%
(255 steps)
This parameter defines the duty-cycle of the PWM applied
to EV3 output (
A33
).
MAX. MOTOR TEMP.
(T, TM, P, CO)
60°C ÷ 175°C
(steps of 1°C)
This parameter defines the motor temperature above
which a 50% cutback is applied to the maximum current.
Cutback is valid only during motoring, while during braking
the 100% of the maximum current is always available
independently by the temperature.
STOP MOTOR TEMP.
(T, TM, P, CO)
60°C ÷ 190°C
(steps of 1°C)
This parameter defines the maximum motor temperature
permitted, above which the controller stops driving the
motor.
A.SENS.MAX SE
(Only for BLE0 with
sin/cos sensor)
(A)
Volt
This parameter records the maximum offset voltage at the
sine analog input during the auto-teaching procedure.
It can be compared with the A.SENS.OFFSET SR entry
value.
A.SENS.MIN SE
(Only for BLE0 with
sin/cos sensor)
(A)
Volt
This parameter records the minimum offset voltage at the
sine analog input during the auto-teaching procedure.
It can be compared with the A.SENS.OFFSET SR entry
value.
A.SENS.MAX CE
(Only for BLE0)
(A)
Volt
This parameter records the maximum offset voltage at the
cosine analog input during the auto-teaching procedure.
It can be compared with the A.SENS.OFFSET CR entry
value.
A.SENS.MIN CE
(Only for BLE0 with
sin/cos sensor)
(A)
Volt
This parameter records the minimum offset voltage at the
cosine analog input during the auto-teaching procedure
.
It can be compared with the A.SENS.OFFSET CR entry
value.
MAN.OFFSET ANGLE
(Only for BLE0)
(A)
0° - 180°
(steps of 0.1°)
This parameter gives the possibility to manually adjust the
offset angle present between the absolute position sensor
and the PMSM rotor orientation. The unit is degrees and
the max value is 180°.
MOT.T. T.CUTBACK
(A)
0% - 100%
(256 steps)
This parameter defines the motor thermal cutback. The
control linearly reduces the motor torque basing on the
motor temperature. Reference limits of the linear reduction
are MAX MOTOR TEMP and TEMP. MOT. STOP.
See paragraph 9.14.
BAT.ENERGY SAVER
(T, TM, P)
OFF ÷ ON
When set to ON, this parameter enables the possibility to
save the battery charge when it has reached a certain
value, through a maximum torque reduction.
Summary of Contents for ACE0 2mC
Page 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Page 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Page 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Page 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Page 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...