Page – 106/155
AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
Error code
Effect
Condition
Restart
procedure
MDI /
LED
CODE
CAN
OPEN
CODE
ZAPI
CODE
WAIT MOT.P STILL
Valve, pump, traction stopped,
LC opened, EB applied
Start-up
45
FFBA
186
HANDBRAKE
Traction/Pump motor is stopped
Start-up, stand-by,
running
Traction/Pump
request
46
FFDD
221
MOT.PHASE SH.
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Start-up
Traction/Pump
request
47
FFC4
196
THROTTLE PROG.
MC remains closed, EB is
applied (the command is
released), Traction stopped
Start-up, Stand-by,
running
Valves or
Traction/Pump
Request
48
FFF3
243
LIFT+LOWER
Pump is stopped
Start-up, stand-by,
running
Pump request
49
FFBB
187
PUMP VACC NOT OK
Traction/Pump motor is stopped
Start-up, stand-by,
running
Lift/lower
potentiometer at
rest
50
FFBC
188
TILLER OPEN
LC opens
Start-up, stand-by,
running
Valves or
Traction/Pump
Request
51
0000
228
PUMP I=0 EVER
MC is open, EB is applied (the
command is released), DC pump
stopped
Running Pump
request
52
2312
52
STBY I HIGH
MC is not closed, EB is applied,
Traction/Pump stopped
Start-up, stand-by
Valves or
Traction/Pump
request
53
2311
53
PUMP I NO ZERO
MC is open, EB is applied (the
command is released), DC pump
stopped
Running Pump
request
56
FFBF
191
OVERLOAD
MC is not closed, EB is applied,
Traction/Pump stopped
Running
Valves or
Traction/Pump
request
57
FFB4
180
WRONG ZERO
MC is opened, EB is applied,
Traction/Pump, valves stopped
Start-up
Valves or
Traction/Pump
request
58
3201
252
CAPACITOR CHARGE
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Start-up
Valves or
Traction/Pump
request
60
3130
60
THERMIC SENS. KO
Maximum current is reduced
according to parameter MOT.T.
T.CUTBACK and speed is
reduced to a fixed value.
Start-up, stand-by,
running
61
4211
250
TH. PROTECTION
Traction controller reduces the
max current linearly from Imax
(85°C) down to 0 A (105°C)
Start-up, stand-by,
running
62
4210
62
BRAKE RUN OUT
Traction is stopped
Start-up, stand-by,
running
Traction/Pump
Request
63
FFCC
204
TILLER ERROR
Traction stopped, EB applied
Stand-by, running
H&S input
released
64
FFB9
185
MOTOR TEMPERAT.
Maximum current is linearly
reduced (see paragraph 9.14)
and speed is reduced to a fixed
value.
Start-up, stand-by,
running
65
4110
65
MOTOR TEMP. STOP
EB is applied, Traction/Pump,
valves stopped
Start-up, stand-by,
running
65
FFB2
178
NO CAN MSG.
MC is opened, EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
request
67
8130
248
SENS MOT TEMP KO
Maximum current is reduced
according to parameter MOT.T.
T.CUTBACK and speed is
reduced to a fixed value.
Start-up, stand-by,
running
68
4311
218
SMARTDRIVER KO
MC is not closed,
Traction/Pump, valves stopped
Start-up Traction
request
69
3302
193
EPS RELAY OPEN
Traction/Pump motor is stopped
Start-up, stand-by,
Running
Valves or
Traction/Pump
request
70
FFCD
205
WRONG RAM MEM.
MC is opened, EB is applied,
Traction/Pump, valves stopped
Stand-by Key
re-cycle
71
FFD2
210
DRIVER SHORTED
MC is opened (the command is
released), EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
request
74
3211
74
Summary of Contents for ACE0 2mC
Page 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Page 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Page 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Page 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Page 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...