AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
Page – 55/155
PARAMETER CHANGE
Parameter
Allowable range
Description
3RD PUMP SPEED
(P)
0% ÷ 100%
(steps of 1%)
This parameter defines the speed of the pump motor when
3
rd
speed is requested. It represents a percentage of the
maximum pump speed.
4TH PUMP SPEED
(P)
0% ÷ 100%
(steps of 1%)
This parameter defines the speed of the pump motor when
4
th
speed is requested. It represents a percentage of the
maximum pump speed.
5TH PUMP SPEED
(P)
0% ÷ 100%
(steps of 1%)
This parameter defines the speed of the pump motor when
5
th
speed is requested. It represents a percentage of the
maximum pump speed.
HYD PUMP SPEED
(P)
0% ÷ 100%
(steps of 1%)
This parameter defines the speed of the pump motor used
for the steering, when HYDRO FUNCTION is ON. It
represents a percentage of the maximum pump speed.
CUTBACK SPEED 1
(T, TM, P)
10% ÷ 100%
(steps of 1%)
This parameter defines the maximum speed performed
when cutback input 1 is active. It represents a percentage
of TOP MAX SPEED.
CUTBACK SPEED 2
(T, TM, P)
10% ÷ 100%
(steps of 1%)
This parameter defines the maximum speed performed
when cutback input 2 is active. It represents a percentage
of TOP MAX SPEED.
H&S CUTBACK
(T, TM)
10% ÷ 100%
(steps of 1%)
This parameter defines the maximum speed performed
when the Hard-and-Soft function is active. It represents a
percentage of TOP MAX SPEED.
CTB. STEER ALARM
(T, TM)
0% ÷ 100%
(steps of 1%)
This parameter defines the maximum traction speed when
an alarm from the EPS is read by the microcontroller, if the
alarm is not safety-related. The parameter represents a
percentage of TOP MAX SPEED.
CURVE SPEED 1
(T, TM)
0% ÷ 100%
(steps of 1%)
This parameter defines the maximum traction speed when
the steering angle is equal to the STEER ANGLE 1 angle.
The parameter represents a percentage of TOP MAX
SPEED.
CURVE CUTBACK
(T, TM)
1% ÷ 100%
(steps of 1%)
This parameter defines the maximum traction speed when
the steering angle is equal to the STEER ANGLE 2 angle.
The parameter represents a percentage of TOP MAX
SPEED.
FREQUENCY CREEP
(T, TM, P)
0.6 Hz ÷ 25 Hz
(steps of 0.1 Hz)
This parameter defines the minimum speed when the
forward- or reverse-request switch is closed, but the
accelerator is at its minimum.
TORQUE CREEP
(T, TM, P, CO)
0% ÷ 100%
(steps of 1/255)
This parameter defines the minimum torque applied when
torque control is enabled and the forward- or
reverse-request switch is closed, but the accelerator is at
its minimum.
MAX. CURRENT TRA
(T, TM, P, CO)
0% ÷ 100%
(steps of 1%)
This parameter defines the maximum current applied to
the motor during acceleration, as a percentage of the
factory-calibrated maximum current.
MAX. CURRENT BRK
(T, TM, P, CO)
0% ÷ 100%
(steps of 1%)
This parameter defines the maximum current applied to
the motor during deceleration, as a percentage of the
factory-calibrated maximum current.
Summary of Contents for ACE0 2mC
Page 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Page 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Page 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Page 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Page 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...