Page – 64/155
AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
SET OPTIONS
Parameter
Allowable range
Description
AUX OUT FUNCTION
(A)
NONE, BRAKE
This parameter enables or disables the NEB output (
A4
),
dedicated to the electromechanical brake.
NONE =
Diagnoses are masked and E.B. is not driven
upon a traction request.
BRAKE =
E.B. is driven upon a traction request if all
the related diagnoses pass. The behavior on a slope
depends on the STOP ON RAMP setting.
Do not use this setting if the electromechanical
brake is not really present.
Note:
in applications with two controllers driving two
traction motors and only one E.B., this parameter has to be
set on BRAKE only in the controller that drives the E.B. .
SYNCRO
(CO)
OFF ÷ ON
This parameter enables or disables the syncro message.
OFF =
The syncro message is not used.
ON =
The syncro message is enabled.
AUTO PARK BRAKE
(CO)
OFF ÷ ON
This parameter enables or disables the autonomous
management of the brake.
OFF =
E.B. is activated or deactivated according to the
signal received via CAN bus.
ON =
E.B. is managed by the controller itself ignoring
any activation/deactivation signal received via CAN
bus.
AUTO LINE CONT.
(CO)
OFF ÷ ON
This parameter enables or disables the autonomous
management of the main contactor.
OFF =
Main contactor is opened or closed according to
the signals received by CAN bus.
ON =
Main contactor is managed by the controller itself
ignoring any activation/deactivation signal received via
CAN bus.
ACCEL MODULATION
(T, TM, P, CO)
OFF ÷ ON
This parameter enables or disables the acceleration-
modulation function.
OFF =
The acceleration rate is inversely proportional to
the ACCEL DELAY parameter.
ON =
The acceleration ramp is inversely proportional to
the ACCEL DELAY parameter only if speed setpoint is
greater than 100 Hz. Below 100 Hz the acceleration
ramp is also proportional to the speed setpoint, so that
the acceleration duration results equal to ACCEL
DELAY.
See paragraph 9.4.
EVP TYPE
(A)
NONE ÷ DIGITAL
This parameter defines the behavior of output EVP1 (
A24
).
NONE =
Output
A24
is not enabled.
ANALOG =
Output
A24
manages a PWM-modulated
current-controlled proportional valve.
DIGITAL =
Output
A24
manages an on/off valve.
Summary of Contents for ACE0 2mC
Page 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Page 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Page 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Page 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Page 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...