Page – 50/155
AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
battery voltage (see paragraph 8.2.3).
-
Check the wiring and that all commands are functioning. Use the
TESTER function to have a real-time feedback about their state.
-
Perform the accelerator acquisition using the PROGRAM VACC
procedure (see paragraph 9.1).
-
Set the maximum current for lift and lowering in MAX. CURRENT TRA
and MAX. CURRENT BRK (see paragraph 8.2.1).
-
Set the motor-related parameters. It is suggested to discuss them with
Zapi technicians.
-
Set parameter SET MOT.TEMPERAT according to the type of motor
thermal sensor adopted.
-
Set the acceleration delay (ACCEL MODULATION and ACCEL DELAY
parameters). Test the behavior in both directions.
-
Set the FREQUENCY CREEP starting from 0.3 Hz. The pump should
just run when the request is active. Increase the level accordingly.
-
Set speed reduction as required by your specifications (see parameter
HB ON / SR OFF in list SET OPTIONS).
-
Set the other performance-related parameters such as
MAX SPEED LIFT, 1ST SPEED COARSE, 2ND SPEED COARSE,
3RD SPEED COARSE.
-
Set the parameters related to hydraulic steering, such as
HYD SPEED FINE and HYDRO TIME.
-
Test the pump in all operative conditions (with and without load, etc.).
At the end of your modifications, re-cycle the key switch to make them effective.
Summary of Contents for ACE0 2mC
Page 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Page 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Page 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Page 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Page 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...