PEV NOT OK
(MDI/LED code = 25)
Cause:
Terminal PCOM is not connected to the battery or the voltage is different
from that defined by parameter SET POSITIVE PEB (see the
ADJUSTMENTS list, paragraph 8.2.3).
This alarm can occur if output NAUX1 is present (and the related setting is
active) or the AUX OUT function is active.
Troubleshooting:
-
Check PCOM terminal: it must be connected to the battery voltage (after
the main contactor).
-
Set the nominal PCOM voltage in parameter SET POSITIVE PEB in
ADJUSTMENTS list (see paragraph 8.2.3).
POS. EB. SHORTED
(MDI/LED code = 84)
Cause:
The voltage on pin
A2
is high even if the smart driver is turned OFF.
Troubleshooting:
-
Verify that the parameter POSITIVE E.B. is set in accordance with the
actual coil positive supply (see paragraph 8.2.5).
-
Check if there is a short or a low impedance path between pin
A2
and of
the +B. In case no failures/problems have been found, the problem is in
the controller, which has to be replaced.
POSITIVE LC OPEN
(MDI/LED code = 35)
Cause
The positive voltage of LC is different from expected.
Troubleshooting
-
Verify LC coil is properly connected.
-
Verify CONF. POSITIVE LC parameter is set in accordance with the
actual coil positive supply (see paragraph 8.2.5). Software, depending on
the parameter value, makes a proper diagnosis; a mismatch between the
hardware and the parameter configuration could generate a false fault.
-
In case no failures/problems have been found, the problem is in the
controller, which has to be replaced.
POWER MISMATCH
(MDI/LED code = 39)
Cause
The error between the power setpoint and the estimated power is out of
range.
Troubleshooting
Ask for assistance to a Zapi technician about the correct adjustment of the
motor parameters.
POWERMOS SHORTED
(MDI/LED code = 89)
Cause
The DC-link voltage drops to zero when a high-side or low-side MOSFET is
turned on.
Troubleshooting
-
Check that motor phases are correctly connected.
-
Check that there is no dispersion to ground for every motor phases.
Summary of Contents for ACE0 2mC
Page 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Page 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Page 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Page 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Page 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...