Page – 104/155
AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
Error code
Effect
Condition
Restart
procedure
MDI /
LED
CODE
CAN
OPEN
CODE
ZAPI
CODE
ENCODER D.ERR XX
Traction is stopped running
Key
re-cycle
3
FFA9
169
HOME SENS.ERR XX
MC is opened , EB is applied,
EVP stopped
Running
Key re-cycle
3
FFB0
176
OFFSET SPD.SENS.
EB is applied, Traction/Pump,
valves stopped.
Start-up
Perform ABS
SENS. ACQUIRE
3
FF99
153
PWM ACQ. ERROR
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Start-up Key
re-cycle
6
FFA4
164
ED SLIP MISMATCH
MC is opened, EB is applied,
Traction/Pump stopped
Running
Valves or
Traction/Pump
request
7
FFA3
163
WATCHDOG
MC is opened, EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by,
running
Key re-cycle
8
6010
8
EVP DRIVER OPEN
MC is opened (the command is
released), EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by,
running
Valves request
9
FFF8
240
EVP COIL OPEN
Valves stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
request
9
5002
214
EVP DRIV. SHORT.
MC is opened , EB is applied,
EVP stopped
Start-up, stand-by,
running
Traction/Pump
request
9
5003
215
EVP2 DRIVER OPEN
MC is opened (the command is
released), EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by,
running
Valves request
10
FFB8
184
EVP2 COIL OPEN
Valves stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
request
10
50F2
182
EVP2 DRIV. SHORT
MC is opened , EB is applied,
EVP stopped
Start-up, stand-by,
running
Traction/Pump
request
10
50F3
183
STALL ROTOR
Traction/Pump stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
request
11
FFD3
211
CONTROLLER MISM.
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Start-up
Install the correct
software and Key
re-cycle
12
FFEF
239
EEPROM KO
Controller works using default
parameters
Start-up, stand-by,
running
13
3610
208
PARAM RESTORE
No effect
Start-up
Traction/Pump
request
14
0000
209
SEAT MISMATCH
MC is not closed, EB is applied,
Traction/Pump stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
request
15
FFDE
222
HW FAULT EV.
MC is not closed, EB is applied,
Traction/Pump stopped
Start-up Key
re-cycle
16
FFEE
238
LOGIC FAILURE #3
MC is opened, EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by
Valves or
Traction/Pump
request
17
FF11
17
LOGIC FAILURE #2
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by,
Valves or
Traction/Pump
request
18
FF12
18
LOGIC FAILURE #1
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Stand-by, running
Valves or
Traction/Pump
request
19
5114
19
VKEY OFF SHORTED
MC is not closed, EB is applied,
Traction/Pump stopped
Start-up Key
re-cycle
20
5101
220
CONT. DRV. EV
Valves stopped
Start-up, stand-by,
running
Valves request
21
FFE8
232
DRV. SHOR. EV
Valves stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
request
21
FFF9
234
OPEN COIL EV.
MC remains closed, EB is
applied, Traction/Pump, valves
stopped (the command is
released)
Start-up, Stand-by,
running
Valves or
Traction/Pump
Request
21
FFF2
242
Summary of Contents for ACE0 2mC
Page 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Page 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Page 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Page 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Page 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...