Page – 134/155
AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
OUT MISMATCH PU
(MDI/LED code = 20)
Cause:
This is a safety related test. Supervisor
μ
C has detected that master
μ
C is
driving the pump motor in a wrong way (not corresponding to the operator
request).
Troubleshooting:
-
Checks the matching of the parameters between Master and Supervisor.
-
Ask for assistance to a Zapi technician.
-
If the problem is not solved, replace the logic board.
PARAM RESTORE
(MDI/LED code = 14)
Cause:
The controller has restored the default settings. If a CLEAR EEPROM has
been made before the last key re-cycle, this warning informs you that
EEPROM was correctly cleared.
Troubleshooting:
-
A travel demand or a pump request cancels the alarm.
-
If the alarm appears at key-on without any CLEAR EEPROM performed,
replace the controller.
SP MISMATCH XX
(MDI/LED code = 15)
Cause:
This is a safety related test. The supervisor
μ
C has detected a mismatch in
the speed setpoint with respect to the master
μ
C. The hexadecimal value
“XX” facilitates Zapi technicians debugging the problem.
Troubleshooting:
-
Check the matching of the parameters between master and supervisor.
-
Ask for assistance to a Zapi technician.
-
If the problem is not solved, replace the logic board.
SP MISMATCH PUMP
(MDI/LED code = 18)
Cause:
This is a safety related test. The supervisor
μ
C has detected a mismatch in
the DC-pump speed setpoint with respect to the master
μ
C.
Troubleshooting:
-
Check the matching of the parameters between master and supervisor.
-
Ask for assistance to a Zapi technician.
-
If the problem is not solved, replace the logic board.
STEER SENSOR KO
(MDI/LED code = 95)
Cause:
The voltage read by the microcontroller at the steering-sensor input is not
within the range from STEER RIGHT VOLT to STEER LEFT VOLT,
programmed through the STEER ACQUIRING function (see paragraph 9.3).
Troubleshooting:
-
Acquire the maximum and minimum values from the steering
potentiometer through the STEER ACQUIRING function.
-
Check the mechanical calibration and the functionality of the
potentiometer.
-
If the problem is not solved, replace the logic board.
Summary of Contents for ACE0 2mC
Page 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Page 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Page 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Page 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Page 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...