Page – 136/155
AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
WRONG SLAVE VER.
(MDI/LED code = 91)
Cause:
Wrong software version on supervisor uC.
Troubleshooting:
Upload the correct software version or ask for assistance to a Zapi
technician.
10.5 Info code for electrovalves
Errors related to HW circuits driving electrovalves (CONT DRV. EV, DRV. SHOR.
EV) are followed by an info code which helps to detect which EV circuit is
affected by the problem.
EVs are coded with a hexadecimal number:
-
02:
EV1 (
A9
)
-
04:
EV2 (
A11
)
-
08:
EV3 (
A33
)
-
20:
EV4 (
A34
)
-
80:
EV5 (
A8
)
If more than one EV circuit is found to be faulty, the code shown corresponds to
the sum of the single info codes. This results in the following table of possibilities,
where faulty EVs are marked with an “F”.
Info
code
EV1
EV2
EV3
EV4
EV5
Info
code
EV1
EV2
EV3
EV4
EV5
02
F
80
F
04
F
82
F
F
06
F
F
84
F
F
08
F
86
F
F
F
0A
F
F
88
F
F
0C
F
F
8A
F
F
F
0E
F
F
F
8C
F
F
F
20
F
8E
F
F
F
F
22
F
F
A0
F
F
24
F
F
A2
F
F
F
26
F
F
F
A4
F
F
F
28
F
F
A6
F
F
F
F
2A
F
F
F
A8
F
F
F
2C
F
F
F
AA
F
F
F
F
2E
F
F
F
F
AC
F
F
F
F
AE
F
F
F
F
F
Summary of Contents for ACE0 2mC
Page 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Page 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Page 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Page 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Page 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...