AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
Page – 107/155
Error code
Effect
Condition
Restart
procedure
MDI /
LED
CODE
CAN
OPEN
CODE
ZAPI
CODE
CONTACTOR DRIVER
MC is opened (the command is
released), EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
request
75
3221
75
MC-EF COIL SHOR.
MC is opened, EB is applied,
Traction/Pump, valves stopped
Start-up
(immediately after
MC closing),
stand-by, running
Valves or
Traction/Pump
request
76
2250
223
VDC LINK OVERV.
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Stand-by, running
Valves or
Traction/Pump
request
77
FFCA
202
VACC NOT OK
Traction/Pump motor is stopped
Start-up, stand-by,
running
Accelerator at rest
78
FF4E
78
INCORRECT START
Traction/Pump motor is stopped Start-up,
stand-by Traction
request
79
FF4F
79
PUMP INC START
Pump motor is stopped
Start-up, stand-by,
running
Pump request
79
FFBD
189
FORW + BACK
Traction is stopped
Start-up, stand-by,
running
Traction request
80
FF50
80
SPEED FB. ERROR
MC is opened , EB is applied,
EVP stopped
Running
Valves or
Traction/Pump
request
81
FFAF
175
ENCODER ERROR
MC is opened, EB is applied,
Traction/Pump, valves stopped
Running
Valves or
Traction/Pump
request
82
FF52
82
WRONG ENC SET
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Start-up
Key re-cycle
83
FF51
181
POS. EB. SHORTED
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Start-up
Traction request
84
3223
195
VACC OUT RANGE
Traction/Pump motor is stopped
Start-up, Stand-by,
Running
Traction/Pump
request
85
FFE2
226
VDC OFF SHORTED
MC is not closed, EB is applied,
Traction/Pump, valves stopped
Start-up, Stand-by,
Running
Key re-cycle
88
FFC8
200
POWERMOS SHORTED
MC is opened, EB is applied,
traction/pump stopped
Start-up
Key re-cycle
89
FFE9
233
PUMP VACC RANGE
DC Pump motor is stopped
Start-up, stand-by
Pump request
90
FFC0
192
WRONG SLAVE VER.
MC opened, EB is applied,
Traction/Pump, valves stopped
Start-up Key
re-cycle
91
FFC5
197
CURRENT GAIN
Controller works, but with low
maximum current
Start-up, stand-by
92
6302
236
PARAM TRANSFER
MC stays closed, EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by,
running
Key re-cycle
93
FFC7
199
STEER SENSOR KO
Speed is reduced according to
parameter CTB. STEER ALARM
(PARAMETER CHANGE list,
paragraph 8.2.1)
Start-up, stand-by,
running
Return into
correct range
95
FFB3
179
ANALOG INPUT
MC is opened, EB is applied,
traction/pump stopped
Stand-by, running
Key re-cycle
96
FFFA
237
M/S PAR CHK MISM
MC stays closed, EB is applied,
Traction/Pump, valves stopped
Start-up
Save again the
parameter and
Key re-cycle
97
FFC6
198
TORQUE PROFILE
EB is applied, Traction/Pump
motor is stopped
Start-up, stand-by
Valves or
Traction/Pump
request
98
FFC9
201
CTRAP THRESHOLD
MC is opened, EB is applied,
Traction/Pump, valves stopped
Start-up, stand-by,
running
Valves or
Traction/Pump
request
99
FFEB
235
10.3.1 Troubleshooting of alarms from master µC
ACQUIRE ABORT
(MDI/LED code = 2)
Cause:
The acquiring procedure relative to the absolute feedback sensor aborted.
Summary of Contents for ACE0 2mC
Page 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Page 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Page 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Page 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Page 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...