10-16
IM 253710-01E
Setting the equation for corrected power
4.
Press the [Pc Formula] soft key to display the equation setting dialog box for
corrected power.
• Selecting the applicable standard
5.
Turn the jog shuttle to select the standard for [Pc Formula].
6.
Press the SELECT key to select either [IEC76-1(1976), IEEE C57.12.90-1993]
or [IEC76-1(1993)].
• Setting the coefficient
(When the applicable standard of the equation is [IEC76-1(1976), IEEE
C57.12.90-1993])
7.
Turn the jog shuttle to select [P1=].
8.
Press the SELECT key. A box used to set coefficient P1 appears.
9.
Turn the jog shuttle to set coefficient P1.
For the procedures related to entering values using the jog shuttle, see section 4.1,
“Entering Values and Strings.”
10.
Press the SELECT key or the ESC key to close the setting box.
11.
Turn the jog shuttle to select [P2=].
12.
Press the SELECT key. A box used to set coefficient P2 appears.
13.
Turn the jog shuttle to set coefficient P2.
For the procedures related to entering values using the jog shuttle, see section 4.1,
“Entering Values and Strings.”
14.
Press the SELECT key or the ESC key to close the setting box.
10.4 Setting the Equations for Apparent Power and Corrected Power