5-37
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
Command
Function
Page
:SERialbus<x>:SENT:TRENd<y>:CUR
Queries the vertical value between cursors on the SENT signal analysis
:SERialbus<x>:SENT:TRENd<y>:CUR
Sets or queries the automated measurement mode of the SENT signal
:SERialbus<x>:SENT:TRENd<y>:CUR
Sets or queries the position of the specified cursor on the SENT signal
:SERialbus<x>:SENT:TRENd<y>:CUR
Queries the time value at the specified cursor on the SENT signal analysis
:SERialbus<x>:SENT:TRENd<y>:CUR
Queries the vertical value at the specified cursor on the SENT signal analysis
:SERialbus<x>:SENT:TRENd<y>:DIS
Sets or queries whether to show (ON) or hide (OFF) the SENT signal
:SERialbus<x>:SENT:TRENd<y>:FCO
Sets or queries the frame control value on the SENT signal analysis trend
:SERialbus<x>:SENT:TRENd<y>:HRA
Sets or queries the SENT signal analysis trend display source window.
:SERialbus<x>:SENT:TRENd<y>:SID
Sets or queries the slow channel ID of the SENT signal analysis trend display
:SERialbus<x>:SENT:TRENd<y>:SOU
Sets or queries the SENT signal analysis trend display source channel.
:SERialbus<x>:SENT:TRENd<y>:UDA
Sets or queries the fast channel user-defined data of the SENT signal
:SERialbus<x>:SENT:TRENd<y>:VER
Sets or queries the vertical range of the SENT signal analysis trend display. 5-222
:SERialbus<x>:SENT:TRENd<y>:VTD
Sets or queries the on/off status of the VT waveform display on the SENT
signal analysis trend display.
Queries all analysis and search settings.
:SERialbus<x>:SOURce:{CHANnel<y
Queries all source waveform settings.
:SERialbus<x>:SOURce:{CHANnel<y
Sets or queries a source waveform hysteresis.
:SERialbus<x>:SOURce:{CHANnel<y
Sets or queries a source waveform level.
Queries all user-defined bus signal analysis and search settings.
:SERialbus<x>:SPATtern:ANALyze?
Queries all user-defined bus signal analysis execution settings.
:SERialbus<x>:SPATtern[:ANALyze
Queries all user-defined bus signal analysis settings.
:SERialbus<x>:SPATtern[:ANALyze
Sets or queries the bit rate for user-defined bus signal analysis.
:SERialbus<x>:SPATtern[:ANALyze
Queries all clock signal settings for user-defined bus signal analysis.
:SERialbus<x>:SPATtern[:ANALyze
Sets or queries the clock signal enable or disable status for user-defined bus
:SERialbus<x>:SPATtern[:ANALyze
Sets or queries the clock signal slope for user-defined bus signal analysis.
:SERialbus<x>:SPATtern[:ANALyze
Sets or queries the clock signal for user-defined bus signal analysis.
:SERialbus<x>:SPATtern[:ANALyze
Queries all chip select signal settings for user-defined bus signal analysis.
:SERialbus<x>:SPATtern[:ANALyze
Sets or queries the chip select signal active state for user-defined bus signal
:SERialbus<x>:SPATtern[:ANALyze
Sets or queries the chip select signal for user-defined bus signal analysis.
:SERialbus<x>:SPATtern[:ANALyze
Queries all data signal settings for user-defined bus signal analysis.
:SERialbus<x>:SPATtern[:ANALyze
Sets or queries the data signal active state for user-defined bus signal
:SERialbus<x>:SPATtern[:ANALyze
Sets or queries the data signal for user-defined bus signal analysis.
:SERialbus<x>:SPATtern[:ANALyze
Queries all latch signal settings for user-defined bus signal analysis.
:SERialbus<x>:SPATtern[:ANALyze
Sets or queries the latch signal slope for user-defined bus signal analysis.
5.1 List of Commands