:ANALysis:PANalyze<x>:SETup:I:PROBe
Function
Queries all current-to-voltage conversion ratio
settings for the current input channel probe for
power supply analysis.
Syntax
F:ANALysis:PANalyze<x>:SETup:I:
PROBe {C0_001|C0_002|C0_005|C0_01|
C0_02|C0_05|C0_1|C0_2|C0_5|C1|C2|C5|
C10|C20|C50|C100|C200|C500|C1000|
C2000}}
:ANALysis:PANalyze<x>:SETup:I:PROBe?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:SETUP:I:PROBE C0
_001
:ANALYSIS:PANALYZE1:SETUP:I:PROBE?
-> :ANALYSIS:PANALYZE1:SETUP:I:
PROBE C0_001
:ANALysis:PANalyze<x>:SETup:U?
Function
Queries all voltage input channel settings for
power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:U?
<x> = 1 to 2
:ANALysis:PANalyze<x>:SETup:U:DESKew
Function
Sets or queries the deskew setting of the voltage
input channel for power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:U:DESK
ew {<Time>}
:ANALysis:PANalyze<x>:SETup:U:DESK
ew?
<x> = 1 to 2
<Time> = −100.0 ns to 100.0 ns (in 10-ps steps)
Example
:ANALYSIS:PANALYZE1:SETUP:U:DESK
EW 1NS
:ANALYSIS:PANALYZE1:SETUP:U:DESKEW?
-> :ANALYSIS:PANALYZE1:SETUP:U:DESK
EW ? 1.000E−09
:ANALysis:PANalyze<x>:SETup:U:INPut
Function
Sets or queries the voltage input channel for
power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:U:INP
ut {1|3}
:ANALysis:PANalyze<x>:SETup:U:INPut?
Example
:ANALYSIS:PANALYZE1:SETUP:U:INPUT 1
:ANALYSIS:PANALYZE1:SETUP:U:INPUT?
-> :ANALYSIS:PANALYZE1:SETUP:U:INPU
T 1
:ANALysis:PANalyze<x>:SETup?
Function
Queries all power supply analysis input settings.
Syntax
:ANALysis:PANalyze<x>:SETup?
<x> = 1 to 2
:ANALysis:PANalyze<x>:SETup:ADESkew
Function
Executes automatic deskewing for power supply
analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:ADESkew
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:SETUP:ADESKEW
:ANALysis:PANalyze<x>:SETup:I?
Function
Queries all current input channel settings for
power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:I?
<x> = 1 to 2
:ANALysis:PANalyze<x>:SETup:I:DESKew
Function
Sets or queries the deskew setting of the current
input channel for power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:I:DESK
ew {<Time>}
:ANALysis:PANalyze<x>:SETup:I:DESK
ew?
<x> = 1 to 2
<Time> = −100.0 ns to 100.0 ns (in 10-ps steps)
Example
:ANALYSIS:PANALYZE1:SETUP:I:DESK
EW 1NS
:ANALYSIS:PANALYZE1:SETUP:I:DESKEW?
-> :ANALYSIS:PANALYZE1:SETUP:I:DESK
EW ? 1.00E−09
:ANALysis:PANalyze<x>:SETup:I:INPut
Function
Sets or queries the current input channel for
power supply analysis.
Syntax
:ANALysis:PANalyze<x>:SETup:I:INP
ut {2|4}
:ANALysis:PANalyze<x>:SETup:I:INPut?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:SETUP:I:INPUT 2
:ANALYSIS:PANALYZE1:SETUP:I:INPUT?
-> :ANALYSIS:PANALYZE1:SETUP:I:INPU
T 2