5-317
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
5.37 XY Group
:XY<x>:MEASure:CURSor:DY?
Function
Queries all settings for the voltage difference
between the XY display’s vertical cursors.
Syntax
:XY<x>:MEASure:CURSor:DY?
<x> = 1 to 4
:XY<x>:MEASure:CURSor:DY:STATe
Function
Sets or queries the on/off status of the voltage
difference between the XY display’s vertical
cursors.
Syntax
:XY<x>:MEASure:CURSor:DY:STATe {<Boo
lean>}
:XY<x>:MEASure:CURSor:DY:STATe?
<x> = 1 to 4
Example
:XY1:MEASURE:CURSOR:DY:STATE ON
:XY1:MEASURE:CURSOR:DY:STATE?
-> :XY1:MEASURE:CURSOR:DY:STATE 1
:XY<x>:MEASure:CURSor:DY:VALue?
Function
Queries the voltage difference between theXY
display’s vertical cursors.
Syntax
:XY<x>:MEASure:CURSor:DY:VALue?
<x> = 1 to 4
Example
:XY1:MEASURE:CURSOR:DY:VALUE?
-> :XY1:MEASURE:CURSOR:DY:VALUE 6.00
0E+00
:XY<x>:MEASure:CURSor:X<y>?
Function
Queries all horizontal cursor settings for the XY
display.
Syntax
:XY<x>:MEASure:CURSor:X<y>?
<x> = 1 to 4
<y> = 1 to 2
:XY<x>:MEASure:CURSor:X<y>:POSition
Function
Sets or queries a horizontal cursor position in the
XY display.
Syntax
:XY<x>:MEASure:CURSor:X<y>:POSiti
on {<NRf>}
:XY<x>:MEASure:CURSor:X<y>:POSition?
<x> = 1 to 4
<y> = 1 to 2
<NRf> = −4 to 4 (div)
Example
:XY1:MEASURE:CURSOR:X1:POSITION 1
:XY1:MEASURE:CURSOR:X1:POSITION?
-> :XY1:MEASURE:CURSOR:X1:POSITION 1
.000E+00
:XY<x>?
Function
Queries all XY display settings.
Syntax
:XY<x>?
<x> = 1 to 4
:XY<x>:DISPlay
Function
Sets or queries the on/off status of the XY display.
Syntax
:XY<x>:DISPlay {<Boolean>}
:XY<x>:DISPlay?
<x> = 1 to 2
Example
:XY1:DISPLAY ON
:XY1:DISPLAY?
-> :XY1:DISPLAY 1
:XY<x>:MEASure?
Function
Queries all automated measurement settings for
the XY display.
Syntax
:XY<x>:MEASure?
<x> = 1 to 4
:XY<x>:MEASure:CURSor?
Function
Queries all cursor measurement settings for the
XY display.
Syntax
:XY<x>:MEASure:CURSor?
<x> = 1 to 4
:XY<x>:MEASure:CURSor:DX?
Function
Queries all settings for the voltage difference
between theXY display’s horizontal cursors.
Syntax
:XY<x>:MEASure:CURSor:DX?
<x> = 1 to 4
:XY<x>:MEASure:CURSor:DX:STATe
Function
Sets or queries the on/off status of the voltage
difference between theXY display’s horizontal
cursors.
Syntax
:XY<x>:MEASure:CURSor:DX:STATe {<Boo
lean>}
:XY<x>:MEASure:CURSor:DX:STATe?
<x> = 1 to 4
Example
:XY1:MEASURE:CURSOR:DX:STATE ON
:XY1:MEASURE:CURSOR:DX:STATE?
-> :XY1:MEASURE:CURSOR:DX:STATE 1
:XY<x>:MEASure:CURSor:DX:VALue?
Function
Queries the voltage difference between theXY
display’s horizontal cursors.
Syntax
:XY<x>:MEASure:CURSor:DX:VALue?
<x> = 1 to 4
Example
:XY1:MEASURE:CURSOR:DX:VALUE?
-> :XY1:MEASURE:CURSOR:DX:VALUE 6.00
0E+00