5-5
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
Command
Function
Page
:ANALysis:PMEAsure<x>:UDPRoxima
Sets or queries the distal, mesial, and proximal points as percentages.
:ANALysis:PMEAsure<x>:UDPRoxima
Sets or queries the distal, mesial, and proximal points as voltages.
Sets or queries the high and low points.
Sets or queries the watthour unit.
:ANALysis:PMEAsure<x>:USER<y>?
Queries all automatic measurement settings for a Calc item.
:ANALysis:PMEAsure<x>:USER<y>:C
Queries the statistical processing count of the automatically measured value
:ANALysis:PMEAsure<x>:USER<y>:D
Sets or queries the expression for the automatically measured value of a
:ANALysis:PMEAsure<x>:USER<y>:
{MAXimum|MEAN|MINimum|SDEViati
Queries a statistical value that is calculated on the automatically measured
:ANALysis:PMEAsure<x>:USER<y>:N
Sets or queries the name of a Calc item.
:ANALysis:PMEAsure<x>:USER<y>:S
Sets or queries the on/off status of automated measurement of a Calc item. 5-78
:ANALysis:PMEAsure<x>:USER<y>:U
Sets or queries the unit of a Calc item.
:ANALysis:PMEAsure<x>:USER<y>:V
Queries the automatically measured value of a Calc item.
Waits for the completion of automated measurement with a set timeout.
Queries all calibration settings.
Sets or queries the on/off status of auto calibration.
Queries all vertical axis settings of a channel.
Executes auto scaling of a channel.
Sets or queries the input filter setting of a channel.
Sets or queries the input coupling setting of a channel.
Sets or queries the deskew setting of a channel.
Sets or queries the display on/off status of a channel.
Sets or queries the on/off status of invert mode, which inverts the waveform
Queries all waveform label settings of a channel.
Sets or queries the waveform label of a channel.
Sets or queries the waveform label display on/off status of a channel.
Queries all linear scaling settings of a channel.
Sets or queries a scaling coefficient A value.
Sets or queries an offset B value.
Sets or queries the on/off status of linear scaling.
Sets or queries a unit that is attached to linear scaling results.
Sets or queries the offset voltage of a channel.
Sets or queries the vertical position of a channel.
Queries all probe attenuation settings of a channel.
Performs demagnetization and zero adjustment on each channel.
Sets or queries the probe attenuation setting of a channel.
Executes zero calibration of current probes for a channel.
Sets or queries the voltage scale of a channel in 0.01 V/division steps.
Sets or queries the voltage scale (in V/division) of a channel.
5.1 List of Commands