5-220
IM DLM4038-17EN
:SERialbus<x>:SENT:SEARch[:SETup]:SD
ATa:SHORt:ID:DECimal<y>
Function
Sets the SENT signal search slow channel short
type ID in decimal notation.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:SD
ATa:SHORt:ID:DECimal<y> {<NRf>}
:SERialbus<x>:SENT:SEARch[:SETup]:SD
ATa:SHORt:ID:DECimal<y>?
<x> = 1 to 4
<y> = 1 or 2
Example
:SERIALBUS1:SENT:SEARCH:SETUP:SDATA:
SHORT:ID:DECimal1 0
:SERIALBUS1:SENT:SEARCH:SETUP:SDATA:
SHORT:ID:DECIMAL1?
-> :SERIALBUS1:SENT:SEARCH:SETUP:SDA
TA:SHORT:ID:DECIMAL1 0
:SERialbus<x>:SENT:SEARch[:SETup]:SD
ATa:SHORt:ID:MODE
Function
Sets or queries the short type ID enable/disable
condition of the SENT signal search slow
channel.
Syntax
:SERialbus<x>:SENT:SEARch[:SETup]:SD
ATa:SHORt:ID:MODE {<Boolean>}
:SERialbus<x>:SENT:SEARch[:SETup]:SD
ATa:SHORt:ID:MODE?
<x> = 1 to 4
Example
:SERIALBUS1:SENT:SEARCH:SETUP:SDATA:
SHORT:ID:MODE ON
:SERIALBUS1:SENT:SEARCH:SETUP:SDATA:
SHORT:ID:MODE?
-> :SERIALBUS1:SENT:SEARCH:SETUP:SDA
TA:SHORT:ID:MODE 1
:SERialbus<x>:SENT:TRENd<y>?
Function
Queries all SENT signal analysis trend display
settings.
Syntax
:SERialbus<x>:SENT:TRENd<y>?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:SENT:TRENd<y>:ASCale
Function
Executes auto scaling of the SENT signal
analysis trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:ASCale
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:SENT:TREND1:ASCALE
:SERialbus<x>:SENT:TRENd<y>:CURSor?
Function
Queries all SENT signal analysis trend display
cursor measurement settings.
Syntax
:SERialbus<x>:SENT:TRENd<y>:CURSor?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:SENT:TRENd<y>:CURSor:D
T:VALue?
Function
Queries the time value between cursors on the
SENT signal analysis trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:CURSor:D
T:VALue?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:SENT:TRENd<y>:CURSor:D
V:VALue?
Function
Queries the vertical value between cursors on the
SENT signal analysis trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:CURSor:D
V:VALue?
<x> = 1 to 4
<y> = 1 to 4
:SERialbus<x>:SENT:TRENd<y>:CURSor:M
ODE
Function
Sets or queries the automated measurement
mode of the SENT signal analysis trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:CURSor:M
ODE {<Boolean>}
:SERialbus<x>:SENT:TRENd<y>:CURSor:M
ODE?
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:SENT:TREND1:CURSOR:MO
DE ON
:SERIALBUS1:SENT:TREND1:CURSOR:MODE?
-> :SERIALBUS1:SENT:TREND1:CURSOR:MO
DE 1
:SERialbus<x>:SENT:TRENd<y>:CURSor:P
OSition<z>
Function
Sets or queries the position of the specified
cursor on the SENT signal analysis trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:CURSor:P
OSition<z> {<NRf>}
:SERialbus<x>:SENT:TRENd<y>:CURSor:P
OSition<z>?
<x> = 1 to 4
<y> = 1 to 4
<z> = 1 or 2
<NRf> = −5 to 5 divisions (in steps of 10
divisions/display record length)
Example
:SERIALBUS1:SENT:TREND1:CURSOR:POSIT
ION1 2
:SERIALBUS1:SENT:TREND1:CURSOR:POSIT
ION1?
-> :SERIALBUS1:SENT:TREND1:CURSOR:PO
SITION1 2.00E+00
5.25 SERialbus Group