5-222
IM DLM4038-17EN
:SERialbus<x>:SENT:TRENd<y>:UDATa
Function
Sets or queries the fast channel user-defined
data of the SENT signal analysis trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:UDATa {<
NRf>}
:SERialbus<x>:SENT:TRENd<y>:UDATa?
<x> = 1 to 4
<y> = 1 to 4
<NRf> = 1 to 4
Example
:SERIALBUS1:SENT:TREND1:UDATA 1
:SERIALBUS1:SENT:TREND1:UDATA?
-> :SERIALBUS1:SENT:TREND1:UDATA 1
:SERialbus<x>:SENT:TRENd<y>:VERTical
Function
Sets or queries the vertical range of the SENT
signal analysis trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:VERTic
al {<NRf>,<NRf>}
:SERialbus<x>:SENT:TRENd<y>:VERTic
al?
<x> = 1 to 4
<y> = 1 to 4
<NRf> = –1.0000E+31 to 1.0000E+31
Example
:SERIALBUS1:SENT:TREND1:VERTIC
AL 1,-1
:SERIALBUS1:SENT:TREND1:VERTICAL?
-> :SERIALBUS1:SENT:TREND1:VERTIC
AL 1.000,-1.000
:SERialbus<x>:SENT:TRENd<y>:VTDispl
ay
Function
Sets or queries the on/off status of the VT
waveform display on the SENT signal analysis
trend display.
Syntax
:SERialbus<x>:SENT:TRENd<y>:VTDispl
ay {<Boolean>}
:SERialbus<x>:SENT:TRENd<y>:VTDispl
ay?
<x> = 1 to 4
<y> = 1 to 4
Example
:SERIALBUS1:SENT:TREND1:VTDISPLAY ON
:SERIALBUS1:SENT:TREND1:VTDISPLAY?
-> :SERIALBUS1:SENT:TREND1:VTDISPLA
Y 1
:SERialbus<x>:SOURce?
Function
Queries all analysis and search settings.
Syntax
:SERialbus<x>:SOURce?
<x> = 1 to 4
:SERialbus<x>:SOURce:{CHANnel<y>|MAT
H<y>}?
Function
Queries all source waveform settings.
Syntax
:SERialbus<x>:SOURce:{CHANnel<y>|MAT
H<y>}?
<x> = 1 to 4
<y> of CHANnel<y> = 1 to 8
<y> of MATH<y> = 1 to 4
:SERialbus<x>:SOURce:{CHANnel<y>|MAT
H<y>}:HYSTeresis
Function
Sets or queries a source waveform hysteresis.
Syntax
:SERialbus<x>:SOURce:{CHANnel<y>|MAT
H<y>}:HYSTeresis {<NRf>}
:SERialbus<x>:SOURce:{CHANnel<y>|
MATH<y>}:HYSTeresis?
<x> = 1 to 4
<y> of CHANnel<y> = 1 to 8
<y> of MATH<y> = 1 to 4
<NRf> = See the DLM4000 Features Guide for
this information.
Example
:SERIALBUS1:SOURCE:CHANNEL1:HYSTERES
IS 1
:SERIALBUS1:SOURCE:CHANNEL1:HYSTERES
IS?
-> :SERIALBUS1:SOURCE:CHANNEL1:HYSTE
RESIS 1.000E+00
:SERialbus<x>:SOURce:{CHANnel<y>|MAT
H<y>}:LEVel
Function
Sets or queries a source waveform level.
Syntax
:SERialbus<x>:SOURce:{CHANnel<y>|MAT
H<y>}:LEVel {<Voltage>,<Voltage>}
:SERialbus<x>:SOURce:{CHANnel<y>|MAT
H<y>}:LEVel?
<x> = 1 to 4
<y> of CHANnel<y> = 1 to 8
<y> of MATH<y> = 1 to 4
<Voltage> = See the DLM4000 Features Guide
for this information.
Example
:SERIALBUS1:SOURCE:CHANNEL1:LEVEL 0V
:SERIALBUS1:SOURCE:CHANNEL1:LEVEL?
-> :SERIALBUS1:SOURCE:CHANNEL1:LEVE
L 0.000E+00
:SERialbus<x>:SPATtern?
Function
Queries all user-defined bus signal analysis and
search settings.
Syntax
:SERialbus<x>:SPATtern?
<x> = 1 to 4
:SERialbus<x>:SPATtern:ANALyze?
Function
Queries all user-defined bus signal analysis
execution settings.
Syntax
:SERialbus<x>:SPATtern:ANALyze?
<x> = 1 to 4
:SERialbus<x>:SPATtern[:ANALyze]:SET
up?
Function
Queries all user-defined bus signal analysis
settings.
Syntax
:SERialbus<x>:SPATtern[:ANALyze]:SET
up?
<x> = 1 to 4
5.25 SERialbus Group