5.2 Totalization Function
5.2.1 Totalized Value and Unit Setting
This product has two totalizers for TB in addition to IT FB. A process value which can be set for
the totalizer on the TB side is a volumetric flow rate, mass flow rate, and calorie.
When Totalizer 1 and Totalizer 2 are selected as the channel of the AI function block, a unit can
be set with following steps in 5.1.4 Engineering Unit Setting.
The set unit can be displayed with the following parameters.
Menu path
Display
Device setup ► Detailed setup ► Totalizer ► (see below)
F
OUNDATION
Fieldbus
Device Configuration ► STB ► Device Configuration ► Configuration ► Totalizer ► (see
below)
Block
Name
Relative
Index
Parameter
Description
Display
F
OUNDATION
Fieldbus
STB
48
Totalizer 1 ► Unit
Total 1 Unit
Displays the unit of totalizer 1.
STB
50
Totalizer 2 ► Unit
Total 2 Unit
Displays the unit of totalizer 2.
5.2.2 Totalized Value Display and Totalization Counter
Function
The totalization result can be displayed with a totalized value or a totalized value which is scaled
with the conversion factor (totalized count value). When the totalized value is scaled with the
conversion factor, a specific flow rate is totalized in 1-count increments, which can be used as a
totalizer counter.
The totalized value can be displayed and configured with the following parameters.
Displaying totalized value
Menu path
Display
Device setup ► Process variables ► Totalizer ► (see below)
F
OUNDATION
Fieldbus
Process Variables ► STB ► Process Variables ► Dynamic Variables ► Device Variables
► (see below)
Block
Name
Relative
Index
Parameter
Description
Display
F
OUNDATION
Fieldbus
STB
47
-
Total 1 Value ► Total 1 Value.
Status
Status of totalizer 1.
Totalizer 1
Total 1 Value ► Total 1 Value.Value
Displays the value of
totalizer 1.
STB
49
-
Total 2 Value ► Total 2 Value.
Status
Status of totalizer 2.
Totalizer 2
Total 2 Value ► Total 2 Value.Value
Displays the value of
totalizer 2.