<6. Parameter Lists>
193
IM 01E21A02-03EN
Relative
Index
Index
Parameter Name
Default Value
Write
Mode
Description
95
2595
LIMIT_STS_
FLN2_ACT_
DIRECTION
0(Low limit)
O/S
5.3.1 ■ Flow noise limit switch
96
2596
LIMIT_
STS_FLN2_
HYSTERESIS
0
O/S
5.3.1 ■ Flow noise limit switch
97
2597
LIMIT_STS_
FLN2_UNIT
50500(cm/s)
-
5.3.1 ■ Flow noise limit switch
98
2598
LIMIT_STS_
CNDC1_VALUE
0
0
-
-
5.3.1 ■ Conductivity limit switch
99
2599
LIMIT_STS_
CNDC1_
SETPOINT
0
O/S
5.3.1 ■ Conductivity limit switch
100
2600
LIMIT_STS_
CNDC1_ACT_
DIRECTION
1(High limit)
O/S
5.3.1 ■ Conductivity limit switch
101
2601
LIMIT_STS_
CNDC1_
HYSTERESIS
0
O/S
5.3.1 ■ Conductivity limit switch
102
2602
LIMIT_STS_
CNDC1_UNIT
50501(mS/cm)
-
5.3.1 ■ Conductivity limit switch
103
2603
LIMIT_STS_
CNDC2_VALUE
0
0
-
-
5.3.1 ■ Conductivity limit switch
104
2604
LIMIT_STS_
CNDC2_
SETPOINT
0
O/S
5.3.1 ■ Conductivity limit switch
105
2605
LIMIT_STS_
CNDC2_ACT_
DIRECTION
0(Low limit)
O/S
5.3.1 ■ Conductivity limit switch
106
2606
LIMIT_STS_
CNDC2_
HYSTERESIS
0
O/S
5.3.1 ■ Conductivity limit switch
107
2607
LIMIT_STS_
CNDC2_UNIT
50501(mS/cm)
-
5.3.1 ■ Conductivity limit switch
108
2608
LIMIT_STS_ADH_
WARNING
0
0
-
-
Judges ON/OFF operation
concerning the adhesion warning.
109
2609
LIMIT_STS_ADH_
ALARM
0
0
-
-
Judges ON/OFF operation
concerning the adhesion alarm.
110
2610
LIMIT_STS_FLN_
WARNING
0
0
-
-
Judges ON/ OFF operation
concerning the flow noise warning.
111
2611
LIMIT_STS_FLN_
ALARM
0
0
-
-
Judges ON/ OFF operation
concerning the flow noise alarm.
112
2612
LIMIT_STS_
LOW_CNDC_
WARNING
0
0
-
-
Judges ON/ OFF operation
concerning the low conductivity
warning.
113
2613
DIAG_
INFORMATION_1 0
-
Parameter for service
114
2614
DIAG_
INFORMATION_2 0
-
Parameter for service
115
2615
DIAG_
INFORMATION_3 0
-
Parameter for service
116
2616
DIAG_
INFORMATION_4 0
-
Parameter for service
117
2617
DIAG_
INFORMATION_5 0
-
Parameter for service
118
2618
DIAG_
INFORMATION_6 0
-
Parameter for service