8-2
168283-1CD
168283-1CD
Hardware Installation &
Software Upgrade
8 MLX200 Specification
8.1 Specification List
8.1
Specification List
8.1.1 Panel Heat Loss (Estimate)
Table 8-1 "Total Amplifier Power Loss"
does not include heat from the
external regenerative resistor unit.
Drive
Panel
Construction
Free-standing, open sub panel
Dimensions
Refer to following
Cooling System
Indirect cooling
Ambient
Temperature
-5
°
C to + 55
°
C (During operation)
-5
°
C to + 55
°
C (During transit and storage)
Relative Humidity
10% to 85%RH (non-condensing)
Power Supply (24 VDC)
Allen Bradley
Grounding
Grounding resistance: 100
Ω
or less
Exclusive grounding
Digital I/O
- None provided
- Add in via PLC modules
Positioning System
By serial communication
(absolute encoder)
Drive Unit
SERVOPACK for AC servomotors
Acceleration/
Deceleration
Software servo control
Memory Capacity
PLC processor dependent
Table 8-1: Total Amplifier Power Loss
Model Type
Power Loss [Watts (W)]
MH5S, MH5S
II,
MH5LS, MH5LS
II
196
MH12
308
HP20D
368
MPK50
1049
MPL80, MPL80
II
961
MPL160, MPL160
II
MPL300, MPL300
II
1130