42
YASKAWA
TOEPC710616134G AC Drive L1000A Technical Manual Addendum
Figure 6.9 V4 Long Travel (DCP3)
Time-Optimized Short Travel at Lift Speed V4 :
1. Before the travel starts, the speed mode "Fast [bit G7]" (V4) is transmitted.
2. The travel starts with activation of travel command bit B1.
3. In contrast to above sequence, travel command bit B1 is switched off before fast speed (V4) is reached. The
same fixed remaining distance (SV4) as for the long travel is traversed when slowing down to crawl speed
(V0).
Figure 6.10 V4 Short Travel (DCP3)
Summary of Contents for L1000A CIMR-LC F Series
Page 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Page 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Page 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Page 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...