Date/Time Message from Lift Controller
The lift controller transmits the message after each initialization message ('I' '0') plus once per day (preferred at
"day changeover").
If the lift controller doesn't support this message type, no Date/Time-message will be received by the drive
controller. In this case, the drive controller has to operate without a synchronization of the clock.
Response to Switching Function Message from Drive Controller
As confirmation, the drive controller sends the following message to the lift controller.
STX
1C
'I'
'3'
ETX
"Emergency Power Supply"/"Energy Saving Mode" Message ('I' '6')
After switching on the emergency supply, the drive controller is sending information to the drive controller. With
this information, the drive controller is able to execute the travel with reduced energy consumption. The Energy
Saving Mode is enabled only in case of CLV/PM control mode.
"Emergency Power Supply"/"Energy Saving Mode" Message from Lift Controller
After switching on the emergency supply, the drive controller is sending the following message.
STX
1C
'I'
'6'
Power Supply
Energy Saving Mode
ETX
When no message ('I' '6') is sent, normal mains operation without energy-saving mode is set up.
Power Supply :
'N' Normal mains operation
'U' Emergency supply
The
’
U
’
request is taken by the drive controller to reduce the regular undervoltage level
[L2-05]
of the drive. In
this condition, the UV level is at 50 V for 400 V units, and at 25 V for 200 V units.
Energy Saving Mode :
'0' No energy saving mode - normal operation
'1' Energy saving mode 1 (In CLV/PM AC Drive control mode only)
'2' Energy saving mode 2 (In CLV/PM AC Drive control mode only)
Response to "Emergency Power Supply"/"Energy Saving Mode" Message by Drive Controller
The drive controller responds with the same telegram in case it supports these modes. If a mode is not supported,
it responds with the actual mode it works.
STX
1C
'I'
'6'
Power Supply
Energy Saving Mode
ETX
If the telegram is not supported and the drive does not respond, the controller assumes normal main supply
without energy-saving mode.
When energy-saving modes '1' or '2' are switched ON, parameter
b8-01
is set to 1 when in CLV/PM control mode.
When '0' is transferred,
b8-01
is set back to 0.
Power Supply :
'N' Normal mains operation
'U' Emergency supply (The drive immediately indicates that it is operating below normal undervoltage levels
[L2-
05]
by transferring
’
U
’
)
Energy Saving Mode :
'0' No energy saving mode - normal operation
'1' Energy saving mode 1 (In CLV/PM AC Drive control mode only)
'2' Energy saving mode 2 (In CLV/PM AC Drive control mode only)
EN
Summary of Contents for L1000A CIMR-LC F Series
Page 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Page 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Page 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Page 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...