YASKAWA
TOEPC710616134G AC Drive L1000A Technical Manual Addendum
87
■
Added Digital Outputs
H2-xx Setting (Hex)
Operator Display
Description
75 (175)
TDCC Pulse Outp
TDCC Pulse Output
With every increment of the TDCC, a pulse of 0.5 s pulse width is output.
76 (176)
TDCC AlmLvl Rch
TDCC Alarm Level Reached
Indicates that the TDCC alarm level is reached.
77 (177)
TDCC FltLvl Rchd
TDCC Fault Level Reached
Indicates that the TDCC has reached 0 value.
■
Added Faults and Alarms
Added Faults
Fault
Fault Code
(Hex)
Fault
Display
Description
Cause
Countermeasure
TDCC Fault
6B
TCF
TDCC Fault
Elevator ropes need to be replaced.
Elevator rope lifetime exceeded (TDCC
Counter = 0)
Change ropes. Enter password in
o4-44
and set
o4-40 = 2
to initialize the counter.
This resets the counter to the value of
o4-
42
.
TDCC
EEPROM
Memory Data
Error
6C
TCE
TDCC EEPROM Memory Data Error
Error, while reading the EEPROM section
related to TDCC, while powering on.
EEPROM might be broken
Power off and wait for the drive's DC bus
to discharge. Power on if the "charge"
LED is off. If the problem occurs again,
replace the control board or the whole
drive.
Added Alarms
Fault
Fault Code
(Hex)
Fault
Display
Description
Cause
Countermeasure
TDCC Alarm
4D
TCA
TDCC Alarm
Elevator ropes need to be replaced soon.
Set
o4-40 = 0
to disable the alarm.
The TDCC value fell below the alarm
threshold
[TDCC < o4-41]
.
Replace the ropes soon.
TDCC Setup
4E
TCS
TDCC Setup
The TDCC function needs to be set up.
Set
o4-40 = 0
to disable the alarm. TCS
has higher priority than TCA.
o4-40
is active although no password is
set to activate the function.
Set up TDCC function.
13
Fast Stop - Edge Triggered
◆
Related Parameters and Monitors
■
Added Digital Inputs
H1-xx Setting (Hex)
Operator Display
Description
5E (15E)
Fast-Stop 2 N.O.
Emergency Stop 2 (N.O.)
Deactivation slope: Decelerates with
Emergency Stop Time [C1-09]
triggered by falling edge.
Even if the Emergency Stop command is cleared, the drive will not operate without cycling the Run
command.
Figure 13.1 Emergency Stop Sequence Fast Stop 2 (N.O.)
EN
Summary of Contents for L1000A CIMR-LC F Series
Page 1: ...AC Drive L1000A For Lift Applications Technical Manual Addendum Type CIMR LCxFxxxxxxx 913x Web...
Page 98: ...15 Appendix 98 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 99: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 99 EN...
Page 100: ...15 Appendix 100 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...
Page 101: ...15 Appendix YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum 101 EN...
Page 102: ...15 Appendix 102 YASKAWA TOEPC710616134G AC Drive L1000A Technical Manual Addendum...