Figure 11.1 Direct Landing Positioning Sequence
■
C5-13 & C5-14 ASR Set Activation
When you activate the Direct Landing input Function via digital input
5Fh [Start Positioning]
, ASR set C5-13/
C5-14 becomes active (motor speed <
C5-07
).
■
Profile Selection for Direct Landing
Depending on the remaining
S5-15 [Positioning Distance]
at the time when digital input
5Fh [Start Positioning]
is activated, there are two profiles. One of them is selected automatically.
Profile 1 :
The time set in
C1-02
is adapted while
C2-04
is fully executed. This leads to a linear deceleration. This profile is
selected when:
Figure 11.2 Profile 1: With Linear Deceleration